Liquid chromatography with multi-channel electrochemical detection for the determination of epigallocatechin gallate in rat plasma utilizing an automated blood sampling device

Hong Long, Yongxin Zhu, Meloney Cregor, Feifei Tian, Lou Coury, Candice B Kissinger, Peter T Kissinger
{"title":"Liquid chromatography with multi-channel electrochemical detection for the determination of epigallocatechin gallate in rat plasma utilizing an automated blood sampling device","authors":"Hong Long,&nbsp;Yongxin Zhu,&nbsp;Meloney Cregor,&nbsp;Feifei Tian,&nbsp;Lou Coury,&nbsp;Candice B Kissinger,&nbsp;Peter T Kissinger","doi":"10.1016/S0378-4347(01)00365-6","DOIUrl":null,"url":null,"abstract":"<div><p>A liquid chromatography method with multi-channel electrochemical detection was developed for the determination of epigallocatechin gallate (EGCG) in rat plasma. After administration of EGCG, blood samples were periodically collected by Culex (an automated blood sampling robot). EGCG was extracted from 50 μl of diluted blood (blood and saline at a ratio of 1:1) with ethyl acetate. Chromatographic separation was achieved within 10 min using a C<sub>8</sub> (150×4.6 mm) 5 μm column with a mobile phase containing 20 m<em>M</em> sodium monochloroacetate, pH 2.8 and 12% acetonitrile at a flow-rate of 1.2 ml/min. A four-channel detector with glassy carbon electrodes was used with applied potentials of +700, 600, 500, 400 mV vs. Ag/AgCl. The limit of detection was 2 ng/ml at a signal-to-noise ratio of 3:1 and the limit of quantitation was 5 ng/ml. The calibration curve was linear over the range of 5–800 ng/ml. The intra- and inter-assay precisions were in the range of 1.3–4.5% and 2.2–4.4%, respectively. Using this method it was possible to determine plasma concentration following a single dose of EGCG to rats with good accuracy and precision. Thus the pharmacokinetic properties of EGCG in rats can be examined for intravenous, intraperitoneal and oral dosing.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 47-51"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00365-6","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B: Biomedical Sciences and Applications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378434701003656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

A liquid chromatography method with multi-channel electrochemical detection was developed for the determination of epigallocatechin gallate (EGCG) in rat plasma. After administration of EGCG, blood samples were periodically collected by Culex (an automated blood sampling robot). EGCG was extracted from 50 μl of diluted blood (blood and saline at a ratio of 1:1) with ethyl acetate. Chromatographic separation was achieved within 10 min using a C8 (150×4.6 mm) 5 μm column with a mobile phase containing 20 mM sodium monochloroacetate, pH 2.8 and 12% acetonitrile at a flow-rate of 1.2 ml/min. A four-channel detector with glassy carbon electrodes was used with applied potentials of +700, 600, 500, 400 mV vs. Ag/AgCl. The limit of detection was 2 ng/ml at a signal-to-noise ratio of 3:1 and the limit of quantitation was 5 ng/ml. The calibration curve was linear over the range of 5–800 ng/ml. The intra- and inter-assay precisions were in the range of 1.3–4.5% and 2.2–4.4%, respectively. Using this method it was possible to determine plasma concentration following a single dose of EGCG to rats with good accuracy and precision. Thus the pharmacokinetic properties of EGCG in rats can be examined for intravenous, intraperitoneal and oral dosing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全自动采血装置液相色谱-多通道电化学检测大鼠血浆中没食子儿茶素没食子酸酯
建立了多通道电化学液相色谱法测定大鼠血浆中表没食子儿茶素没食子酸酯(EGCG)的方法。给予EGCG后,库蚊(自动采血机器人)定期采集血样。用乙酸乙酯从50 μl稀释后的血液(血与生理盐水按1:1的比例)中提取EGCG。色谱柱为C8 (150×4.6 mm) 5 μm,流动相为20 mm的一氯乙酸钠,pH为2.8,12%乙腈,流速为1.2 ml/min,在10 min内完成分离。采用玻璃碳电极,外加电位分别为+700、600、500、400 mV vs. Ag/AgCl。检测限为2 ng/ml,信噪比为3:1,定量限为5 ng/ml。校正曲线在5 ~ 800 ng/ml范围内呈线性关系。检测内精密度为1.3 ~ 4.5%,检测间精密度为2.2 ~ 4.4%。使用该方法可以测定大鼠单剂量EGCG后的血浆浓度,具有良好的准确性和精密度。因此,EGCG在大鼠体内的药代动力学特性可用于静脉、腹腔和口服给药。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
News Section Influence of various biological matrices (plasma, blood microdialysate) on chromatographic performance in the determination of β-blockers using an alkyl-diol silica precolumn for sample clean-up Highly sensitive analysis of the antifolate pemetrexed sodium, a new cancer agent, in human plasma and urine by high-performance liquid chromatography. Preliminary application of liquid chromatography–electrospray-ionization mass spectrometry to the detection of 5-methyltetrahydrofolic acid monoglutamate in human plasma Improved high-performance liquid chromatographic method to estimate aminosugars and its application to glycosaminoglycan determination in plasma and serum
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1