High-precision multicollector isotopic analysis of low levels of Nd as oxide

M.F. Thirlwall
{"title":"High-precision multicollector isotopic analysis of low levels of Nd as oxide","authors":"M.F. Thirlwall","doi":"10.1016/0168-9622(91)90036-V","DOIUrl":null,"url":null,"abstract":"<div><p>30 ng Nd samples loaded with silica gel and phosphoric acid on single rhenium filaments reproducibly provide <sup>144</sup>NdO<sup>+</sup> ion beams of ∼ 1.5-2 · 10<sup>−11</sup> A for several hours, without need of a poor source vacuum, or need to introduce oxygen into the mass spectrometer source. The loading technique discriminates strongly against CeO<sup>+</sup>, and accurate normalization for mass fractionation to <span><math><msup><mi></mi><mn>142</mn></msup><mtext>Nd</mtext><msup><mi></mi><mn>144</mn></msup><mtext>Nd</mtext></math></span> is possible. A 5-collector procedure for analysis and interference correction (<sup>18</sup>O, <sup>17</sup>O overlaps, CeO<sup>+</sup>, PrO<sup>+</sup>, SmO<sup>+</sup> ) is described which permits analysis of 30 ng Nd loads to internal precision of ±0.000005 (2se) in ∼2.5 hr. 17 loads (each 30 ng) of the laboratory Nd standard (analysed March–June 1990) yielded external precision of ±0.000007 (2sd) on <span><math><msup><mi></mi><mn>143</mn></msup><mtext>Nd</mtext><msup><mi></mi><mn>144</mn></msup><mtext>Nd</mtext></math></span>, and <span><math><msup><mi></mi><mn>143</mn></msup><mtext>Nd</mtext><msup><mi></mi><mn>144</mn></msup><mtext>Nd</mtext></math></span> and <span><math><msup><mi></mi><mn>145</mn></msup><mtext>Nd</mtext><msup><mi></mi><mn>144</mn></msup><mtext>Nd</mtext></math></span> values within 2se of the value determined on 500 ng Nd<sup>+</sup> runs, and a further 17, analysed October 1990–April 1991, give identical results within error. Eight sample analyses also agree within 2se between Nd<sup>+</sup> and NdO+ analyses, the latter being loaded from rinses of the disposable pipette tips used to load the Nd<sup>+</sup> runs.</p></div>","PeriodicalId":100231,"journal":{"name":"Chemical Geology: Isotope Geoscience section","volume":"94 1","pages":"Pages 13-22"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0168-9622(91)90036-V","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Geology: Isotope Geoscience section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/016896229190036V","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

30 ng Nd samples loaded with silica gel and phosphoric acid on single rhenium filaments reproducibly provide 144NdO+ ion beams of ∼ 1.5-2 · 10−11 A for several hours, without need of a poor source vacuum, or need to introduce oxygen into the mass spectrometer source. The loading technique discriminates strongly against CeO+, and accurate normalization for mass fractionation to 142Nd144Nd is possible. A 5-collector procedure for analysis and interference correction (18O, 17O overlaps, CeO+, PrO+, SmO+ ) is described which permits analysis of 30 ng Nd loads to internal precision of ±0.000005 (2se) in ∼2.5 hr. 17 loads (each 30 ng) of the laboratory Nd standard (analysed March–June 1990) yielded external precision of ±0.000007 (2sd) on 143Nd144Nd, and 143Nd144Nd and 145Nd144Nd values within 2se of the value determined on 500 ng Nd+ runs, and a further 17, analysed October 1990–April 1991, give identical results within error. Eight sample analyses also agree within 2se between Nd+ and NdO+ analyses, the latter being loaded from rinses of the disposable pipette tips used to load the Nd+ runs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低浓度氧化钕的高精度多收集器同位素分析
在单铼丝上负载硅胶和磷酸的30 ng Nd样品可重复地提供约1.5-2·10−11 A的144NdO+离子束数小时,而不需要差源真空,也不需要在质谱仪源中引入氧气。加载技术对CeO+有很强的鉴别能力,可以将质量分馏精确归一化为142Nd144Nd。描述了用于分析和干扰校正(18O, 17O重叠,CeO+, PrO+, SmO+)的5收集器程序,该程序允许在~ 2.5小时内分析30 ng Nd负载,内部精度为±0.000005 (2se)。实验室Nd标准的17个负载(每个30 ng)(1990年3月至6月分析)在143Nd144Nd上的外部精度为±0.000007 (2sd), 143Nd144Nd和145Nd144Nd值在500 ng Nd+运行中确定的值的2se内,另外17个负载(1990年10月至1991年4月分析)在误差范围内给出相同的结果。8个样品分析也在2se内同意Nd+和NdO+分析,后者是从用于加载Nd+运行的一次性移液管尖端的冲洗中加载的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Introduction Chemical changes and carbon isotope variations in a cross-section of a large Miocene gymnospermous log The stable isotopic composition of photosynthetic pigments and related biochemicals Stable isotope fractionation of biomonomers during protokerogen formation Kinetic fractionation of stable carbon and nitrogen isotopes during peptide bond hydrolysis: Experimental evidence and geochemical implications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1