A helical folded dipole antenna for medical implant communication applications

Basari, Dony Canisius Sirait, F. Zulkifli, E. Rahardjo
{"title":"A helical folded dipole antenna for medical implant communication applications","authors":"Basari, Dony Canisius Sirait, F. Zulkifli, E. Rahardjo","doi":"10.1109/IMWS-BIO.2013.6756247","DOIUrl":null,"url":null,"abstract":"Currently, most of implanted medical devices are using inductive coupling for communication, which leads to difficulty in transmitting medical data records for several meters range. In order for the implanted device is able to be used in longer range transmission, the device is wirelessly transmitted in the form of electromagnetic signals. This initiates us to study on a patient home monitoring system, in which the external devices such as portable equipments will provide a benefit for healthcare provider in accessing the important patient medical information via a networked connection. Because of this reason, an electrically small antenna for implantable devices is very essential components in monitoring systems to provide wirelessly communication between a patient and an access point. In this paper, a helical folded dipole antenna for an implantable device is proposed for wireless patient monitoring system. The implanted device is assumed to be applied by a syringe injection allowing to the device is simply injected into the human body. The proposed antenna is operated in UHF band 924 MHz, as a band of Indonesian RFID applications. The antenna is quite small in comparison to the band operation (ka≈0.08). Sufficient electrical performances are obtained such as reflection coefficient, impedance bandwidth, radiation pattern and gain. According to the link budget analysis, the proposed antenna has adequate gain within 10m transmission range by 225 MHz bandwidth (VSWR ≤ 2).","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":"5 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Currently, most of implanted medical devices are using inductive coupling for communication, which leads to difficulty in transmitting medical data records for several meters range. In order for the implanted device is able to be used in longer range transmission, the device is wirelessly transmitted in the form of electromagnetic signals. This initiates us to study on a patient home monitoring system, in which the external devices such as portable equipments will provide a benefit for healthcare provider in accessing the important patient medical information via a networked connection. Because of this reason, an electrically small antenna for implantable devices is very essential components in monitoring systems to provide wirelessly communication between a patient and an access point. In this paper, a helical folded dipole antenna for an implantable device is proposed for wireless patient monitoring system. The implanted device is assumed to be applied by a syringe injection allowing to the device is simply injected into the human body. The proposed antenna is operated in UHF band 924 MHz, as a band of Indonesian RFID applications. The antenna is quite small in comparison to the band operation (ka≈0.08). Sufficient electrical performances are obtained such as reflection coefficient, impedance bandwidth, radiation pattern and gain. According to the link budget analysis, the proposed antenna has adequate gain within 10m transmission range by 225 MHz bandwidth (VSWR ≤ 2).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于医疗植入通信应用的螺旋折叠偶极子天线
目前,大多数植入式医疗设备都采用电感耦合的方式进行通信,这导致在几米范围内传输医疗数据记录的困难。为了使所植入的装置能够用于更远距离的传输,所述装置以电磁信号的形式进行无线传输。因此,我们开始研究一种患者家庭监控系统,在该系统中,便携式设备等外部设备将有利于医疗保健提供者通过网络连接访问患者的重要医疗信息。由于这个原因,用于植入式设备的电小天线是监测系统中非常重要的组件,可以在患者和接入点之间提供无线通信。本文提出了一种可植入装置的螺旋折叠偶极子天线,用于无线病人监护系统。被植入的装置被假定为通过注射器注射,允许该装置被简单地注射到人体中。该天线工作在UHF频段924 MHz,作为印尼RFID应用的频段。与波段操作(ka≈0.08)相比,天线相当小。获得了充分的电学性能,如反射系数、阻抗带宽、辐射方向图和增益。根据链路预算分析,该天线在225 MHz带宽(VSWR≤2)的10m传输范围内具有足够的增益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Technical program committee Organizing committee Fast, compact and label-free electrical detection of live and dead single cells Why headache using GSM cellular phones? An investigation of microwave ablation for bone thermal drilling
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1