{"title":"In-line rheometry for highly filled suspensions through Doppler ultrasound","authors":"S. Ricci, B. Birkhofer, D. Lootens, P. Tortoli","doi":"10.1109/ULTSYM.2010.5935438","DOIUrl":null,"url":null,"abstract":"For chemical, cosmetic, pharmaceutical, and food industries the rheological properties of a product represent an important quality factor. Unfortunately such features are often difficult to estimate, in particular in a continuous production process. In this work, we present an ultrasound (US) Doppler method suitable for in-line rheological assessment of highly filled opaque suspensions. The velocity profile developed by highly filled and opaque polyurethane based adhesives and sealants flowing in a pipe was measured through a proprietary US board. The high resolution profile was then fitted to the power law model and the wall shear rate (WSR), a reliable rheological indicator in high shear-thinning suspensions, was obtained. The accuracy of the method was evaluated comparing the measured WSR to reference values obtained from off-line laboratory rheometry. The error from 78 measurements at flow rates between 1 and 35 ml/s featured a mean +3.6% bias and a standard deviation below 12%. Moreover, measurements are only minimally affected by the variation of several US parameters over a wide range of values demonstrating the robusness of the technique.","PeriodicalId":6437,"journal":{"name":"2010 IEEE International Ultrasonics Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2010.5935438","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

For chemical, cosmetic, pharmaceutical, and food industries the rheological properties of a product represent an important quality factor. Unfortunately such features are often difficult to estimate, in particular in a continuous production process. In this work, we present an ultrasound (US) Doppler method suitable for in-line rheological assessment of highly filled opaque suspensions. The velocity profile developed by highly filled and opaque polyurethane based adhesives and sealants flowing in a pipe was measured through a proprietary US board. The high resolution profile was then fitted to the power law model and the wall shear rate (WSR), a reliable rheological indicator in high shear-thinning suspensions, was obtained. The accuracy of the method was evaluated comparing the measured WSR to reference values obtained from off-line laboratory rheometry. The error from 78 measurements at flow rates between 1 and 35 ml/s featured a mean +3.6% bias and a standard deviation below 12%. Moreover, measurements are only minimally affected by the variation of several US parameters over a wide range of values demonstrating the robusness of the technique.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过多普勒超声测量高填充悬浮液的在线流变
对于化工、化妆品、制药和食品行业来说,产品的流变性能是一个重要的质量因素。不幸的是,这些特征通常很难估计,特别是在连续生产过程中。在这项工作中,我们提出了一种超声(US)多普勒方法,适用于在线流变评估高度填充的不透明悬浮液。高度填充和不透明的聚氨酯基胶粘剂和密封剂在管道中流动的速度分布是通过专有的美国板测量的。然后将高分辨率剖面拟合到幂律模型中,得到了高剪切减薄悬浮液中可靠的流变指标——壁面剪切率(WSR)。将测量的WSR与离线实验室流变学获得的参考值进行比较,评估了该方法的准确性。在1至35 ml/s的流速下进行的78次测量的误差平均为+3.6%的偏差,标准偏差低于12%。此外,测量仅受几个US参数在广泛范围内的变化的最小影响,这表明了该技术的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Combined use of iteration, quadratic interpolation and an extra kernel for high-resolution 2D particle tracking: A first evaluation Comparing tumor response to VEGF blockade therapy using high frequency ultrasound imaging with size-selected microbubble contrast agents A comparative study of optimal fundamental, second- and superharmonic imaging Evaluation for the distribution of fouling deposition on the microfiltration membrane using high frequency ultrasound A matrix phased array system for 3D high frame-rate imaging of the carotid arteries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1