Comparative Evaluation of Fracture Resistance and Microleakage of Reattached Anterior Tooth Fragment Using Two Different Flowable Composites- An in vitro Study
{"title":"Comparative Evaluation of Fracture Resistance and Microleakage of Reattached Anterior Tooth Fragment Using Two Different Flowable Composites- An in vitro Study","authors":"Saumya, R. Dhingra, Ashish Gupta, B. Karunanand","doi":"10.9734/bjmmr/2017/32526","DOIUrl":null,"url":null,"abstract":"Aim: To evaluate and compare the fracture resistance and microleakage of reattached anterior tooth fragment using two different flowable composites. Study Design: In-vitro study. Place and of Study: The present in vitro study was carried out in the Department between June and July 2016. Methodology: The subjects were selected from various sources. A total of 160 extracted permanent anteriors were selected for the study. Teeth were divided into 2 groups, 80 teeth in each group reattached with G-aenial Universal Flo and Esthet X-Flow, evaluated for fracture resistance testing using Universal testing machine. Half number of teeth tested for microleakage using Dye-penetration method. The results obtained from the study were then tabulated and statistically analyzed. Results: Mean value for fracture resistance in Group I were observed (89.07 ± 32.46) whereas in Group II were observed (64.63 ± 40.33). On statistical analysis result found to be highly significant (p = 0.001). Out of 40 teeth, in Group I -16 observed no penetration whereas in Group II -10 teeth were observed no penetration. On Enamel-Dentin microleakage in Group I found to be in 6 teeth, whereas 14 teeth showed the same Enamel-Dentin penetration in Group II. But on statistical analysis, overall result found to be non-significant (p = 0.19). Conclusion: Among the tested flowable composites, G-aenial Universal Flo showed highly significant fracture resistance than Esthet X-flow. Microleakage shows no significant differences between nanohybrid and microhybrid flowable composites.","PeriodicalId":9249,"journal":{"name":"British journal of medicine and medical research","volume":"9 1","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of medicine and medical research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bjmmr/2017/32526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Aim: To evaluate and compare the fracture resistance and microleakage of reattached anterior tooth fragment using two different flowable composites. Study Design: In-vitro study. Place and of Study: The present in vitro study was carried out in the Department between June and July 2016. Methodology: The subjects were selected from various sources. A total of 160 extracted permanent anteriors were selected for the study. Teeth were divided into 2 groups, 80 teeth in each group reattached with G-aenial Universal Flo and Esthet X-Flow, evaluated for fracture resistance testing using Universal testing machine. Half number of teeth tested for microleakage using Dye-penetration method. The results obtained from the study were then tabulated and statistically analyzed. Results: Mean value for fracture resistance in Group I were observed (89.07 ± 32.46) whereas in Group II were observed (64.63 ± 40.33). On statistical analysis result found to be highly significant (p = 0.001). Out of 40 teeth, in Group I -16 observed no penetration whereas in Group II -10 teeth were observed no penetration. On Enamel-Dentin microleakage in Group I found to be in 6 teeth, whereas 14 teeth showed the same Enamel-Dentin penetration in Group II. But on statistical analysis, overall result found to be non-significant (p = 0.19). Conclusion: Among the tested flowable composites, G-aenial Universal Flo showed highly significant fracture resistance than Esthet X-flow. Microleakage shows no significant differences between nanohybrid and microhybrid flowable composites.