Realtime control of multiple-focus phased array heating patterns based on noninvasive ultrasound thermography

A. Casper, Dalong Liu, E. Ebbini
{"title":"Realtime control of multiple-focus phased array heating patterns based on noninvasive ultrasound thermography","authors":"A. Casper, Dalong Liu, E. Ebbini","doi":"10.1109/ULTSYM.2010.5935977","DOIUrl":null,"url":null,"abstract":"We present results from realtime feedback control of single- and multiple-focus phased array heating patterns based on ultrasound thermography. The results illustrate several important aspects of realtime control of phased array heating patterns as they are envisioned to be used in noninvasive, image-guided thermal therapy applications. First, complex, multiple-focus heating patterns require multi-point, noninvasive temperature feedback that may not be easily available using thermocouple or other invasive proibes. Second, multiple-focus pattern synthesis must be optimized to maintain the highest efficiency of the phased array driver in order to achieve the control objectives. This has led to the development of a dynamic power reallocation algorithm for realtime management of the power share of each focus accoring to maximize its heating rate. Third, realtime integration between the feedback thermography and array driver control with high spatial and temporal resolution is necessary, especially for short exposures used in ablative treatments. These aspects are well illustrated by the results shown: 1) realtime thermography at frame rates up to 100 fps, 2) realtime multiple-focus pattern resynthesis with update rates up to 1000 patterns per second, and 3) an intelligent dynamic power reallocation scheme to distribute the available driving power according to the collective needs of the individual foci in the multiple-focus heating patterns. Without this dynamic power reallocation, the standard multiple-focus pattern synthesis may produce low-efficiency driving patterns that may fail to achieve the control objective at the some or all control points in the heating pattern.","PeriodicalId":6437,"journal":{"name":"2010 IEEE International Ultrasonics Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Ultrasonics Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.2010.5935977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

We present results from realtime feedback control of single- and multiple-focus phased array heating patterns based on ultrasound thermography. The results illustrate several important aspects of realtime control of phased array heating patterns as they are envisioned to be used in noninvasive, image-guided thermal therapy applications. First, complex, multiple-focus heating patterns require multi-point, noninvasive temperature feedback that may not be easily available using thermocouple or other invasive proibes. Second, multiple-focus pattern synthesis must be optimized to maintain the highest efficiency of the phased array driver in order to achieve the control objectives. This has led to the development of a dynamic power reallocation algorithm for realtime management of the power share of each focus accoring to maximize its heating rate. Third, realtime integration between the feedback thermography and array driver control with high spatial and temporal resolution is necessary, especially for short exposures used in ablative treatments. These aspects are well illustrated by the results shown: 1) realtime thermography at frame rates up to 100 fps, 2) realtime multiple-focus pattern resynthesis with update rates up to 1000 patterns per second, and 3) an intelligent dynamic power reallocation scheme to distribute the available driving power according to the collective needs of the individual foci in the multiple-focus heating patterns. Without this dynamic power reallocation, the standard multiple-focus pattern synthesis may produce low-efficiency driving patterns that may fail to achieve the control objective at the some or all control points in the heating pattern.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于无创超声热成像的多焦点相控阵加热模式实时控制
本文介绍了基于超声热成像的单焦点和多焦点相控阵加热模式的实时反馈控制结果。这些结果说明了相控阵加热模式实时控制的几个重要方面,因为它们被设想用于无创、图像引导的热治疗应用。首先,复杂的多焦点加热模式需要多点、非侵入性的温度反馈,而使用热电偶或其他侵入性探针可能不容易获得。其次,为了实现控制目标,必须优化多焦点方向图合成以保持相控阵驱动器的最高效率。这导致了一种动态功率重新分配算法的发展,该算法可以根据最大的加热速率实时管理每个焦点的功率份额。第三,反馈热成像和阵列驱动控制之间的实时集成是必要的,具有高空间和时间分辨率,特别是在烧蚀治疗中使用的短曝光。结果表明:1)帧速率高达100 fps的实时热成像;2)更新速率高达1000帧/秒的实时多焦点模式重新合成;3)一种智能动态功率重新分配方案,根据多焦点加热模式中单个焦点的集体需求分配可用驱动功率。如果没有这种动态功率再分配,标准的多焦点模式综合可能会产生低效率的驱动模式,可能无法在加热模式的某些或所有控制点实现控制目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Combined use of iteration, quadratic interpolation and an extra kernel for high-resolution 2D particle tracking: A first evaluation Comparing tumor response to VEGF blockade therapy using high frequency ultrasound imaging with size-selected microbubble contrast agents A comparative study of optimal fundamental, second- and superharmonic imaging Evaluation for the distribution of fouling deposition on the microfiltration membrane using high frequency ultrasound A matrix phased array system for 3D high frame-rate imaging of the carotid arteries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1