Invited Product Profile ADEXUSDx hCG Capillary Blood Test

Qinwei Shi, Duane Poorman, K. Clark
{"title":"Invited Product Profile ADEXUSDx hCG Capillary Blood Test","authors":"Qinwei Shi, Duane Poorman, K. Clark","doi":"10.1097/POC.0000000000000166","DOIUrl":null,"url":null,"abstract":"Abstract Although many qualitative point-of-care tests are commercially available for detection of pregnancy including urine and serum human chorionic gonadotropin (hCG) tests, these products are often associated with higher risk of false-negative results and are not easy to use. The ADEXUSDx hCG Test uses only 1 drop (35–40 &mgr;L) of whole blood sample for the detection of hCG, making it suitable for capillary blood testing. Comparison with Access Total &bgr;hCG (5th IS) assay using 392 finger stick samples from women of child-bearing age demonstrated an overall agreement of 98.1%. Performance of the ADEXUSDx hCG Test was prospectively evaluated in 40 pregnant and 40 nonpregnant women aged 18 to 44 years. The hCG test generated 100% sensitivity and 100% specificity. Study of additional 318 nonpregnant women in various age groups demonstrated 99.7% specificity. The ADEXUSDx hCG Test is a rapid test (10 minutes) with demonstrated ease of use and clinical performance, making it a useful point-of-care test as well as over-the-counter test.","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000166","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Although many qualitative point-of-care tests are commercially available for detection of pregnancy including urine and serum human chorionic gonadotropin (hCG) tests, these products are often associated with higher risk of false-negative results and are not easy to use. The ADEXUSDx hCG Test uses only 1 drop (35–40 &mgr;L) of whole blood sample for the detection of hCG, making it suitable for capillary blood testing. Comparison with Access Total &bgr;hCG (5th IS) assay using 392 finger stick samples from women of child-bearing age demonstrated an overall agreement of 98.1%. Performance of the ADEXUSDx hCG Test was prospectively evaluated in 40 pregnant and 40 nonpregnant women aged 18 to 44 years. The hCG test generated 100% sensitivity and 100% specificity. Study of additional 318 nonpregnant women in various age groups demonstrated 99.7% specificity. The ADEXUSDx hCG Test is a rapid test (10 minutes) with demonstrated ease of use and clinical performance, making it a useful point-of-care test as well as over-the-counter test.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ADEXUSDx hCG毛细管血液检测
虽然许多定性的即时检测方法在商业上可用于妊娠检测,包括尿液和血清人绒毛膜促性腺激素(hCG)检测,但这些产品往往与假阴性结果的高风险相关,而且不容易使用。ADEXUSDx hCG检测只需要1滴(35-40 μ L)全血样本检测hCG,适用于毛细管血液检测。与使用来自育龄妇女的392个手指棒样本的Access Total &bgr;hCG (5th IS)检测相比,结果总体一致性为98.1%。对40名18至44岁的孕妇和40名非孕妇进行ADEXUSDx hCG测试。hCG测试产生100%的敏感性和100%的特异性。另外318名不同年龄组的未怀孕妇女的研究显示出99.7%的特异性。ADEXUSDx hCG测试是一种快速测试(10分钟),证明易于使用和临床性能,使其成为一种有用的护理点测试以及非处方测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin Critical Care Nurses' Views and Experiences of Preanalytical Factors Influencing Point-of-Care Testing Rapid Assessment of Coagulation at the Point of Care With the Hemochron Signature Elite System Invited Product Profile: Detecting Antibodies for Lyme Disease at the Point of Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1