{"title":"In vitro examination of fracture resistance of 3D-printed resin blocks in different diameters","authors":"K. Topsakal, M. Aksoy, G. S. Duran","doi":"10.25259/apos_170_2022","DOIUrl":null,"url":null,"abstract":"\n\nThe intraoral use of commercial printable polymers in dental patients is still a challenge due to the unknown physical properties of the materials. The present study aimed to comparably evaluate the maximum load and deflection values of three-dimensional-printed resin blocks in different diameters that can be used intraorally in dental patients.\n\n\n\nForty-five cylindrical resin blocks in diameters of 2 mm (Group 1, n = 15), 3 mm (Group 2, n = 15), and 4 mm (Group 3, n = 15) and lengths of 20 mm were designed and printed. The samples were placed in the universal testing device to conduct the 3-point bending test. According to the Shapiro–Wilk normality test results, Kruskal–Wallis and Mann–Whitney U tests were performed for the statistical analysis. The level of statistical significance was accepted as P < 0.05.\n\n\n\nThe values for the maximum load (N) and deflection (mm) in the study groups were 218.4 ± 31.9, 2.96 ± 0.86 in Group 3; 77.05 ± 61.5, 3.91 ± 0.92 in Group 2; and 19.67 ± 2.63, 4.06 ± 1.02 in Group 1, respectively. The mean values of maximum load for Group 3 were superior to Group 2 (P = 0.020) and Group 1 (P = 0.00). Group 2 revealed higher maximum load results than Group 1 (P = 0.003). The mean values of maximum deflection in Group 3 were lower compared to Group 2 (P = 0.014) and Group 1 (P = 005).\n\n\n\nThe results of this in vitro study encourage the use of resin-printed intraoral appliances in place of conventional treatment modalities.\n","PeriodicalId":42593,"journal":{"name":"APOS Trends in Orthodontics","volume":"31 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"APOS Trends in Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/apos_170_2022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
The intraoral use of commercial printable polymers in dental patients is still a challenge due to the unknown physical properties of the materials. The present study aimed to comparably evaluate the maximum load and deflection values of three-dimensional-printed resin blocks in different diameters that can be used intraorally in dental patients.
Forty-five cylindrical resin blocks in diameters of 2 mm (Group 1, n = 15), 3 mm (Group 2, n = 15), and 4 mm (Group 3, n = 15) and lengths of 20 mm were designed and printed. The samples were placed in the universal testing device to conduct the 3-point bending test. According to the Shapiro–Wilk normality test results, Kruskal–Wallis and Mann–Whitney U tests were performed for the statistical analysis. The level of statistical significance was accepted as P < 0.05.
The values for the maximum load (N) and deflection (mm) in the study groups were 218.4 ± 31.9, 2.96 ± 0.86 in Group 3; 77.05 ± 61.5, 3.91 ± 0.92 in Group 2; and 19.67 ± 2.63, 4.06 ± 1.02 in Group 1, respectively. The mean values of maximum load for Group 3 were superior to Group 2 (P = 0.020) and Group 1 (P = 0.00). Group 2 revealed higher maximum load results than Group 1 (P = 0.003). The mean values of maximum deflection in Group 3 were lower compared to Group 2 (P = 0.014) and Group 1 (P = 005).
The results of this in vitro study encourage the use of resin-printed intraoral appliances in place of conventional treatment modalities.