The influence of sampling method on electrolyte concentrations, pH and buffer capacity of saliva in healthy individuals

Biljana Andjelski-Radičević, M. Milošević, I. Dozic
{"title":"The influence of sampling method on electrolyte concentrations, pH and buffer capacity of saliva in healthy individuals","authors":"Biljana Andjelski-Radičević, M. Milošević, I. Dozic","doi":"10.1515/sdj-2016-0011","DOIUrl":null,"url":null,"abstract":"Abstract Introduction Saliva is a complex secretion, which plays an important role in maintenance of oral health. Analysis of saliva is fast, simple and non-invasive, and it is increasingly used as a biological sample for determination of various biochemical markers. The aim was to determine the influence of unstimulated saliva collection methods for measuring electrolytes concentration (sodium, potassium, calcium), pH and buffer capacity of saliva in healthy subjects. Material and methods 30 healthy subjects, males and females, aged 18 to 20 years, without oral and systemic diseases were included in the study. Unstimulated saliva samples were taken using a special tube (Salivette) and via direct spitting into the test tube. The concentrations of sodium and potassium were determined by flame emission photometry while spectrophotometry was used for calcium concentration. For the analysis of pH value of saliva pH-meter was used, while saliva buffer capacity was determined by titration with HCl (0.005 mol/L). Results The level of sodium in unstimulated saliva collected in test tubes was 8.43 ± 3.92 mmol/L and in special tubes 7.90 ± 4.33 mmol/L. Potassium level in unstimulated saliva collected in test tubes was 13.62 ± 0.99 mmol/L while in special tubes it was 13.54 ± 0.94 mmol/L. Mean values of sodium and potassium in unstimulated saliva didn’t show statistically significant difference in their concentrations between the two methods of collecting saliva. In contrast to these electrolytes, calcium concentration was higher in the samples of saliva collected with special tubes (2.04 ± 1.05 mmol/L) compared to the samples taken by direct spitting into the test tube (1.38 ± 1.18 mmol/L) with statistically significant difference (p < 0.05). By analyzing the pH of unstimulated saliva it was found that the average pH value of saliva collected with special tubes was 7.05 ± 0.32, and after direct spitting into test tubes it was 7.35 ± 0.41. Buffer capacity of saliva in healthy subjects was lower after taking with special tubes (5.18 ± 0.74) compared to test tubes (5.36 ± 0.85), but without statistical difference. Conclusion Unstimulated saliva collecting methods using cotton pads (salivette) and direct spitting in the test tube did not affect the value of pH, buffer capacity, the concentrations of sodium and potassium, but affected the concentration of calcium in saliva from healthy subjects.","PeriodicalId":52984,"journal":{"name":"Stomatoloski glasnik Srbije","volume":"15 1","pages":"109 - 116"},"PeriodicalIF":0.0000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stomatoloski glasnik Srbije","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/sdj-2016-0011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Introduction Saliva is a complex secretion, which plays an important role in maintenance of oral health. Analysis of saliva is fast, simple and non-invasive, and it is increasingly used as a biological sample for determination of various biochemical markers. The aim was to determine the influence of unstimulated saliva collection methods for measuring electrolytes concentration (sodium, potassium, calcium), pH and buffer capacity of saliva in healthy subjects. Material and methods 30 healthy subjects, males and females, aged 18 to 20 years, without oral and systemic diseases were included in the study. Unstimulated saliva samples were taken using a special tube (Salivette) and via direct spitting into the test tube. The concentrations of sodium and potassium were determined by flame emission photometry while spectrophotometry was used for calcium concentration. For the analysis of pH value of saliva pH-meter was used, while saliva buffer capacity was determined by titration with HCl (0.005 mol/L). Results The level of sodium in unstimulated saliva collected in test tubes was 8.43 ± 3.92 mmol/L and in special tubes 7.90 ± 4.33 mmol/L. Potassium level in unstimulated saliva collected in test tubes was 13.62 ± 0.99 mmol/L while in special tubes it was 13.54 ± 0.94 mmol/L. Mean values of sodium and potassium in unstimulated saliva didn’t show statistically significant difference in their concentrations between the two methods of collecting saliva. In contrast to these electrolytes, calcium concentration was higher in the samples of saliva collected with special tubes (2.04 ± 1.05 mmol/L) compared to the samples taken by direct spitting into the test tube (1.38 ± 1.18 mmol/L) with statistically significant difference (p < 0.05). By analyzing the pH of unstimulated saliva it was found that the average pH value of saliva collected with special tubes was 7.05 ± 0.32, and after direct spitting into test tubes it was 7.35 ± 0.41. Buffer capacity of saliva in healthy subjects was lower after taking with special tubes (5.18 ± 0.74) compared to test tubes (5.36 ± 0.85), but without statistical difference. Conclusion Unstimulated saliva collecting methods using cotton pads (salivette) and direct spitting in the test tube did not affect the value of pH, buffer capacity, the concentrations of sodium and potassium, but affected the concentration of calcium in saliva from healthy subjects.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采样方法对健康人唾液电解质浓度、pH和缓冲能力的影响
唾液是一种复杂的分泌物,对维持口腔健康起着重要的作用。唾液分析具有快速、简便、无创等特点,越来越多地作为生物样品用于各种生化指标的测定。目的是确定非刺激唾液采集方法对测量健康受试者唾液电解质浓度(钠、钾、钙)、pH值和缓冲能力的影响。材料与方法选取年龄在18 ~ 20岁,无口腔及全身疾病的健康男性和女性30例。使用特殊的唾液管(Salivette)直接将未受刺激的唾液样本吐进试管中。钠、钾浓度采用火焰发射光度法测定,钙浓度采用分光光度法测定。唾液pH值分析采用pH计,唾液缓冲容量测定采用盐酸(0.005 mol/L)滴定法。结果试管采集的非刺激唾液钠含量为8.43±3.92 mmol/L,特殊试管采集的钠含量为7.90±4.33 mmol/L。试管中未刺激唾液钾含量为13.62±0.99 mmol/L,特殊试管中钾含量为13.54±0.94 mmol/L。未刺激唾液中钠和钾的平均值在两种收集唾液的方法中没有统计学差异。与这些电解质相比,专用管采集的唾液中钙浓度(2.04±1.05 mmol/L)高于直接吐痰的唾液(1.38±1.18 mmol/L),差异有统计学意义(p < 0.05)。通过分析未刺激唾液的pH值发现,专用管采集唾液的平均pH值为7.05±0.32,直接吐入试管后唾液的平均pH值为7.35±0.41。健康人唾液缓冲容量(5.18±0.74)低于对照组(5.36±0.85),但差异无统计学意义。结论非刺激唾液采集法(棉垫法)和直接在试管中吐痰法对健康人唾液pH值、缓冲容量、钠、钾浓度无影响,但对唾液钙浓度有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
10
审稿时长
12 weeks
期刊最新文献
An influence of finishing procedures and protective coating on the ultrastructure of conventional and hybrid glass ionomer cement restorations Examination of the presence of periodontitis and gingivitis in rats with induced diabetes mellitus Condylographic evaluation of propulsive and Bennett angles in patients with temporomandibular disorders Cyclic fatigue testing of ProTaper Universal and ProTaper Next rotary instruments of different diameters Oral health behavior and oral hygiene habits of elderly population in Podgorica, Montenegro
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1