Application of FastICA in on-line calibration of the current sensor's phase difference

Guoliang Gong, Huaxiang Lu
{"title":"Application of FastICA in on-line calibration of the current sensor's phase difference","authors":"Guoliang Gong, Huaxiang Lu","doi":"10.1109/ICNC.2012.6234760","DOIUrl":null,"url":null,"abstract":"The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, a phase difference measurement method based on FastICA is proposed to calibrate the phase difference of the current sensor on-line. However, not all source components are mutually independent in our application. Additionally, due to limitations of the algorithm, the phase errors of the separated results are different in different test runs. In order to get an exact result, we have proposed an evaluation index to choose an optimal result from different runs. The index is based on the relationship of mapping components to observed signals. Simulation results indicate that the method presented in this paper is effective and feasible.","PeriodicalId":87274,"journal":{"name":"International Conference on Computing, Networking, and Communications : [proceedings]. International Conference on Computing, Networking and Communications","volume":"15 1","pages":"330-334"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Computing, Networking, and Communications : [proceedings]. International Conference on Computing, Networking and Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICNC.2012.6234760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, a phase difference measurement method based on FastICA is proposed to calibrate the phase difference of the current sensor on-line. However, not all source components are mutually independent in our application. Additionally, due to limitations of the algorithm, the phase errors of the separated results are different in different test runs. In order to get an exact result, we have proposed an evaluation index to choose an optimal result from different runs. The index is based on the relationship of mapping components to observed signals. Simulation results indicate that the method presented in this paper is effective and feasible.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
FastICA在电流传感器相位差在线标定中的应用
在电力设备中,电流传感器的性能会受到环境的影响而变差。本文提出了一种基于FastICA的相位差测量方法,用于在线校准电流传感器的相位差。然而,在我们的应用程序中,并非所有的源组件都是相互独立的。此外,由于算法的限制,在不同的测试运行中,分离结果的相位误差是不同的。为了得到准确的结果,我们提出了一个评价指标,从不同的运行中选择最优的结果。该索引基于映射分量与观测信号的关系。仿真结果表明了该方法的有效性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
BER and HPA Nonlinearities Compensation for Joint Polar Coded SCMA System over Rayleigh Fading Channels Harmonizing Wearable Biosensor Data Streams to Test Polysubstance Detection. eFCM: An Enhanced Fuzzy C-Means Algorithm for Longitudinal Intervention Data. Automatic Detection of Opioid Intake Using Wearable Biosensor. A New Mining Method to Detect Real Time Substance Use Events from Wearable Biosensor Data Stream.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1