Comparative analysis of canal transportation using reciproc blue and wavo one gold in simulated root canals using different kinematics

Mohamed Medhat Kataia , Nehal Nabil Roshdy , Mohamed Mokhtar Nagy
{"title":"Comparative analysis of canal transportation using reciproc blue and wavo one gold in simulated root canals using different kinematics","authors":"Mohamed Medhat Kataia ,&nbsp;Nehal Nabil Roshdy ,&nbsp;Mohamed Mokhtar Nagy","doi":"10.1016/j.fdj.2018.04.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>The purpose of the current study was to assess and compare the shaping ability of WaveOne Gold and Reciproc Blue in reciprocation and counter clock wise rotation using standardized resin blocks and to assess time required to reach full working length.</p></div><div><h3>Methodology</h3><p>A total of 52 curved canals in clear resin blocks with 30° angle of curvature and 16 mm canal length were used in this study. The blocks were divided into 4 groups according to the instrument and motion utilized into: Reciproc Blue/Reciprocation (RB/R) group, Reciproc Blue/counter clock wise rotation (RB/CCW) group, WaveOne gold/Reciprocation (WG/R) and WaveOne gold/Counter clock wise rotation (WO/RCR). Standardized digital images were taken prior and post instrumentation. Then, Adobe Photoshop was used to superimpose post and pre-instrumentation images to evaluate the degree of canal transportation. Digital chronometer was used to record the time required for canal preparation. One-way ANOVA followed by Tukey post hoc test was used to compare between more than two groups in non-related samples.</p></div><div><h3>Results</h3><p>No statistically significant difference was noted among all groups at the apical and middle thirds levels. As for the preparation time, both groups; RB/R and RB/CCW recorded significantly longer time than groups; WG/R and WG/CCW (P &lt; 0.001).</p></div><div><h3>Conclusions</h3><p>The use of single-file in counter clock wise rotation showed favourable results in terms of avoiding canal transportation and preparation time.</p></div>","PeriodicalId":100562,"journal":{"name":"Future Dental Journal","volume":"4 2","pages":"Pages 156-159"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.fdj.2018.04.005","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Future Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2314718018300302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Objective

The purpose of the current study was to assess and compare the shaping ability of WaveOne Gold and Reciproc Blue in reciprocation and counter clock wise rotation using standardized resin blocks and to assess time required to reach full working length.

Methodology

A total of 52 curved canals in clear resin blocks with 30° angle of curvature and 16 mm canal length were used in this study. The blocks were divided into 4 groups according to the instrument and motion utilized into: Reciproc Blue/Reciprocation (RB/R) group, Reciproc Blue/counter clock wise rotation (RB/CCW) group, WaveOne gold/Reciprocation (WG/R) and WaveOne gold/Counter clock wise rotation (WO/RCR). Standardized digital images were taken prior and post instrumentation. Then, Adobe Photoshop was used to superimpose post and pre-instrumentation images to evaluate the degree of canal transportation. Digital chronometer was used to record the time required for canal preparation. One-way ANOVA followed by Tukey post hoc test was used to compare between more than two groups in non-related samples.

Results

No statistically significant difference was noted among all groups at the apical and middle thirds levels. As for the preparation time, both groups; RB/R and RB/CCW recorded significantly longer time than groups; WG/R and WG/CCW (P < 0.001).

Conclusions

The use of single-file in counter clock wise rotation showed favourable results in terms of avoiding canal transportation and preparation time.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在不同运动学的模拟根管内,互惠蓝与波一金对根管运输的比较分析
目的本研究的目的是评估和比较WaveOne Gold和Reciproc Blue在使用标准化树脂块的往复和逆时针旋转中的成型能力,并评估达到完全工作长度所需的时间。方法采用52根弯曲根管,根管长度为16 mm,根管弯曲角度为30°。根据使用的器械和动作将积木分为4组:Reciproc Blue/往复(RB/R)组、Reciproc Blue/逆时针旋转(RB/CCW)组、WaveOne gold/往复(WG/R)组和WaveOne gold/逆时针旋转(WO/RCR)组。在仪器前和仪器后拍摄标准化的数字图像。然后,利用Adobe Photoshop对测量后和测量前的图像进行叠加,评价运河的运输程度。用数字计时器记录预备管所需的时间。在非相关样本中,采用单因素方差分析和Tukey事后检验进行两组以上样本的比较。结果各组间在根尖和中三分之一水平差异无统计学意义。至于准备时间,两组;RB/R和RB/CCW记录时间显著长于各组;WG/R和WG/CCW (P < 0.001)。结论单纵队逆时针旋转,在避免运管和准备时间方面具有良好的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measuring Accuracy of Dolphin Imaging Software in predicting upper jaw soft tissue profile changes in Class II Adult Patients treated with Extraction versus Non-Extraction Success of Early Childhood Caries After Treatment with Silver Diamine Fluoride Compared to conventional Glass Ionomer Restoration. A Systematic Review Comparison of Alignment Duration Between 0.018” And 0.022” Slot Brackets in Non-Extraction Orthodontic Adult Patients: A Randomized Clinical Study The Efficiency of Passive Ultrasonic Activated Irrigation on the Retrievability of Guttaflow Bioseal : In Vitro Study Radiographic Analysis of Umbrella Technique Combined with Sticky Bone in Horizontal Ridge Augmentation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1