Accuracy of cone-beam CT in detecting vertical root fractures in teeth with post-endodontic restorations: an in vitro study

IF 0.1 Q4 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH ACTA SCIENTIARUM-HEALTH SCIENCES Pub Date : 2021-10-13 DOI:10.4025/actascihealthsci.v43i1.55832
F. C. Yamashita, A. L. Yamashita, Irma Milena Menck Romanichen, E. S. Tolentino, S. Sábio, M. Chicarelli, L. Iwaki
{"title":"Accuracy of cone-beam CT in detecting vertical root fractures in teeth with post-endodontic restorations: an in vitro study","authors":"F. C. Yamashita, A. L. Yamashita, Irma Milena Menck Romanichen, E. S. Tolentino, S. Sábio, M. Chicarelli, L. Iwaki","doi":"10.4025/actascihealthsci.v43i1.55832","DOIUrl":null,"url":null,"abstract":"The aim of this study was to evaluate the accuracy of cone-beam CT (CBCT) for the detection of artificially created vertical root fractures (VRF) in extracted teeth restored with metallic (MP) and fiberglass (FGP) posts. After root canal obturation, 60 extracted human premolars were scanned by using the highest-resolution settings of a CBCT unit. The prepared roots were randomly divided into three groups: group C (control group): non-restored and non- endodontically treated teeth (n = 20); group MP (n = 20); group FGP (n = 20). In all groups, 10 teeth were artificially fractured. Two external and independent observers blindly recorded the presence or absence of VRF. Sensitivity, specificity, accuracy, intra- and interobserver agreement were calculated. Kappa value for inter- and intraobserver agreement was 0.82 and 0.84 respectively, demonstrating good agreement. The highest values for sensitivity (0.80 - 0.90), specificity (1.00) and accuracy (0.90 - 0.95) were found in the control group. The teeth with FGP restoration presented the lowest sensitivity (0.30 - 0.50) and accuracy (0.60 - 0.65) values. Both examiners had a good performance in the diagnosis of fractures in teeth with MP, with accuracy ranging between 0.85 - 0.90. The presence of MP did not influence accuracy; however, the presence of FGP reduced the diagnostic capacity of CBCT.","PeriodicalId":42839,"journal":{"name":"ACTA SCIENTIARUM-HEALTH SCIENCES","volume":"170 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2021-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACTA SCIENTIARUM-HEALTH SCIENCES","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4025/actascihealthsci.v43i1.55832","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 1

Abstract

The aim of this study was to evaluate the accuracy of cone-beam CT (CBCT) for the detection of artificially created vertical root fractures (VRF) in extracted teeth restored with metallic (MP) and fiberglass (FGP) posts. After root canal obturation, 60 extracted human premolars were scanned by using the highest-resolution settings of a CBCT unit. The prepared roots were randomly divided into three groups: group C (control group): non-restored and non- endodontically treated teeth (n = 20); group MP (n = 20); group FGP (n = 20). In all groups, 10 teeth were artificially fractured. Two external and independent observers blindly recorded the presence or absence of VRF. Sensitivity, specificity, accuracy, intra- and interobserver agreement were calculated. Kappa value for inter- and intraobserver agreement was 0.82 and 0.84 respectively, demonstrating good agreement. The highest values for sensitivity (0.80 - 0.90), specificity (1.00) and accuracy (0.90 - 0.95) were found in the control group. The teeth with FGP restoration presented the lowest sensitivity (0.30 - 0.50) and accuracy (0.60 - 0.65) values. Both examiners had a good performance in the diagnosis of fractures in teeth with MP, with accuracy ranging between 0.85 - 0.90. The presence of MP did not influence accuracy; however, the presence of FGP reduced the diagnostic capacity of CBCT.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
锥形束CT检测牙髓修复后牙根垂直骨折的准确性:一项体外研究
本研究的目的是评估锥形束CT (CBCT)检测金属(MP)和玻璃纤维(FGP)桩修复拔牙人工制造的垂直根裂(VRF)的准确性。在根管封闭后,使用CBCT装置的最高分辨率设置扫描60颗拔出的人类前磨牙。将准备好的牙根随机分为3组:C组(对照组):未修复和未根管治疗的牙(n = 20);MP组(n = 20);FGP组(n = 20)所有组均人工断牙10颗。两名外部独立观察员盲目地记录了VRF的存在与否。计算灵敏度、特异性、准确性、观察者内部和观察者之间的一致性。观察者之间和观察者内部一致性的Kappa值分别为0.82和0.84,表明一致性良好。对照组的敏感性(0.80 ~ 0.90)、特异性(1.00)和准确性(0.90 ~ 0.95)最高。FGP修复牙的灵敏度(0.30 ~ 0.50)和准确度(0.60 ~ 0.65)最低。两位检查者在MP诊断牙齿骨折方面表现良好,准确率在0.85 - 0.90之间。MP的存在不影响准确性;然而,FGP的存在降低了CBCT的诊断能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACTA SCIENTIARUM-HEALTH SCIENCES
ACTA SCIENTIARUM-HEALTH SCIENCES PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
0.40
自引率
0.00%
发文量
30
审稿时长
40 weeks
期刊介绍: The journal publishes original papers in Health Sciences, such as Clinical Analyses; Physical Education, Nursing, Pharmacy; Pharmacology, Phoniatry and Audiology, Physiotherapy and Occupational Therapy, Medicine, Nutrition, Dentistry and Public Health Policies.
期刊最新文献
Acupuncture effects on pain and health status in women with fibromyalgia: a randomized clinical trial Psychological, physical and sexual violence against brazilian women: a cross-section study Singlet oxygen release due to different concentrations of photosensitizer Adherence by nursing professionals to standard precautions in the COVID-19 pandemic Tomographic evaluation of changes induced by herbst treatment - buccolingual inclination of mandibular canines and the intercanine distance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1