A comparative study of asthma with airflow limitation and asthma-COPD overlap using the forced oscillation technique

Hiroki Sato, A. Tanaka, K. Hirai, T. Ebato, H. Inoue, T. Homma, S. Ohta, S. Suzuki, H. Sagara
{"title":"A comparative study of asthma with airflow limitation and asthma-COPD overlap using the forced oscillation technique","authors":"Hiroki Sato, A. Tanaka, K. Hirai, T. Ebato, H. Inoue, T. Homma, S. Ohta, S. Suzuki, H. Sagara","doi":"10.15369/SUJMS.33.25","DOIUrl":null,"url":null,"abstract":"The forced oscillation technique ( FOT ) , which requires breathing without forced action, is a useful tool that can measure respiratory impedance. We investigated the physiological differences between asthma with smoking-unrelated airflow limitation and asthma-chronic obstructive pulmonary disease ( COPD ) overlap ( ACO ) using the FOT. Among 275 patients with asthma who presented at the Showa University Hospital from April 2018 through March 2019, 211 were enrolled and assigned into the asthma ( BA ) , asthma with airflow limitation ( AL ) , or ACO groups. Respiratory impedance measured using the FOT were compared among the groups. There were no differences in spirometry data between the AL and the ACO group. The AL group had higher respiratory resistance at 5 Hz ( R5 ) , 20 Hz ( R20 ) , and reactance at 5 Hz than the ACO group, but there was no significant difference in subtracting R20 from R5 ( R5 - R20 ) . R5 and R20 were similar between the ACO and the BA groups, but R5 - R20, resonant frequency ( Fres ) , and low-frequency reactance area were significantly higher in the ACO group than the BA group. Fres yielded the highest area under the curve ( AUC ) to identify airflow limitation, and R20 yielded the highest AUC to identify the ACO group among patients with airflow limitation. 33 patients ACO. Therefore, FOT aids our understanding of the physiological characteristics and provides clues for the treatment in asthmatics with airflow limitation.","PeriodicalId":23019,"journal":{"name":"The Showa University Journal of Medical Sciences","volume":"59 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Showa University Journal of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15369/SUJMS.33.25","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The forced oscillation technique ( FOT ) , which requires breathing without forced action, is a useful tool that can measure respiratory impedance. We investigated the physiological differences between asthma with smoking-unrelated airflow limitation and asthma-chronic obstructive pulmonary disease ( COPD ) overlap ( ACO ) using the FOT. Among 275 patients with asthma who presented at the Showa University Hospital from April 2018 through March 2019, 211 were enrolled and assigned into the asthma ( BA ) , asthma with airflow limitation ( AL ) , or ACO groups. Respiratory impedance measured using the FOT were compared among the groups. There were no differences in spirometry data between the AL and the ACO group. The AL group had higher respiratory resistance at 5 Hz ( R5 ) , 20 Hz ( R20 ) , and reactance at 5 Hz than the ACO group, but there was no significant difference in subtracting R20 from R5 ( R5 - R20 ) . R5 and R20 were similar between the ACO and the BA groups, but R5 - R20, resonant frequency ( Fres ) , and low-frequency reactance area were significantly higher in the ACO group than the BA group. Fres yielded the highest area under the curve ( AUC ) to identify airflow limitation, and R20 yielded the highest AUC to identify the ACO group among patients with airflow limitation. 33 patients ACO. Therefore, FOT aids our understanding of the physiological characteristics and provides clues for the treatment in asthmatics with airflow limitation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
应用强迫振荡技术对气流受限哮喘和哮喘-慢性阻塞性肺病重叠的比较研究
强迫振荡技术(FOT)是一种测量呼吸阻抗的有用工具,它要求在没有强迫动作的情况下呼吸。我们使用FOT研究了与吸烟无关的气流限制哮喘和哮喘-慢性阻塞性肺疾病(COPD)重叠(ACO)之间的生理差异。在2018年4月至2019年3月在昭和大学医院就诊的275例哮喘患者中,211例被纳入并分配到哮喘(BA)、哮喘合并气流限制(AL)或ACO组。比较各组呼吸阻抗测量结果。AL组和ACO组的肺活量测量数据无差异。AL组5 Hz呼吸阻力(R5)、20 Hz呼吸阻力(R20)和5 Hz呼吸电抗均高于ACO组,但R5减去R20 (R5 - R20)差异无统计学意义。ACO组R5和R20与BA组相似,但ACO组R5 - R20、共振频率(Fres)和低频电抗面积显著高于BA组。在气流受限患者中,Fres曲线下面积(AUC)最高,R20曲线下面积(AUC)最高,用于识别ACO组。33例ACO。因此,FOT有助于我们了解气流受限哮喘患者的生理特征,并为其治疗提供线索。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Long-term follow-up of production of IgM and IgG antibodies against SARS-CoV-2 among patients with COVID-19 Quantification of gray values corresponding to bone density using dental cone-beam computed tomography Dual Energy CT for determining the severity of acute pancreatitis Clinical significance of blood endocan level in breast cancer patients Objective and subjective interproximal contact between the implant and the natural tooth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1