ENGINEERING FORMULAS FOR ESTIMATING THE INFLUENCE OF NATURAL CONVECTION ALONG THE SURFACE OF FUEL ASSEMBLY OF WWER-1000 ON THE RESULTS OF MEASURING ITS SIZES BY THE ULTRASONIC METHOD IN COOLING POND OF NUCLEAR POWER PLANT

A. Voronina, S. Pavlov
{"title":"ENGINEERING FORMULAS FOR ESTIMATING THE INFLUENCE OF NATURAL CONVECTION ALONG THE SURFACE OF FUEL ASSEMBLY OF WWER-1000 ON THE RESULTS OF MEASURING ITS SIZES BY THE ULTRASONIC METHOD IN COOLING POND OF NUCLEAR POWER PLANT","authors":"A. Voronina, S. Pavlov","doi":"10.55176/2414-1038-2021-1-74-85","DOIUrl":null,"url":null,"abstract":"Engineering formulas are presented for calculating the value of methodological error in measuring the distances from the ultrasonic sensor to the surface of the irradiated fuel assembly of WWER-1000 caused by decay heat from the fuel assembly. The methodical error arises due to the water temperature gradient along ultrasonic wave path. This is due to the presence of natural convection at the surface of the fuel assembly discharged from the reactor into cooling pool at nuclear power plant. The paper presents a methodology for calculating the methodical error. It is assumed that the water temperature between the sensor and the surface of the fuel assembly is determined by convective heat transfer between the fuel assembly and the water in cooling pool at nuclear power plant. The surface of VVER-1000 fuel assemblies is modeled by a flat vertical plate with a uniform surface heat flux. The propagation of an ultrasonic wave in a medium between the surface of a fuel assembly and an ultrasonic sensor is described in the approximation of geometric acoustics. The results of numerical calculations according to the presented method are executed in the form of nomograms. Engineering formulas for calculating the value of methodological error are obtained by processing an array of calculated data. The obtained formulas are used in the development of measuring systems for monitoring the deformation of fuel assemblies of WWER-1000 in cooling pond of nuclear power plant.","PeriodicalId":20426,"journal":{"name":"PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY. SERIES: NUCLEAR AND REACTOR CONSTANTS","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY. SERIES: NUCLEAR AND REACTOR CONSTANTS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.55176/2414-1038-2021-1-74-85","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Engineering formulas are presented for calculating the value of methodological error in measuring the distances from the ultrasonic sensor to the surface of the irradiated fuel assembly of WWER-1000 caused by decay heat from the fuel assembly. The methodical error arises due to the water temperature gradient along ultrasonic wave path. This is due to the presence of natural convection at the surface of the fuel assembly discharged from the reactor into cooling pool at nuclear power plant. The paper presents a methodology for calculating the methodical error. It is assumed that the water temperature between the sensor and the surface of the fuel assembly is determined by convective heat transfer between the fuel assembly and the water in cooling pool at nuclear power plant. The surface of VVER-1000 fuel assemblies is modeled by a flat vertical plate with a uniform surface heat flux. The propagation of an ultrasonic wave in a medium between the surface of a fuel assembly and an ultrasonic sensor is described in the approximation of geometric acoustics. The results of numerical calculations according to the presented method are executed in the form of nomograms. Engineering formulas for calculating the value of methodological error are obtained by processing an array of calculated data. The obtained formulas are used in the development of measuring systems for monitoring the deformation of fuel assemblies of WWER-1000 in cooling pond of nuclear power plant.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
给出了核电站冷却池中wwer-1000燃料组件表面自然对流对超声测量结果影响的工程计算公式
给出了计算WWER-1000辐照燃料组件的衰减热引起的超声传感器到燃料组件表面距离的方法误差值的工程公式。水温沿超声波路径的梯度会引起方法误差。这是由于从反应堆排放到核电站冷却池的燃料组件表面存在自然对流。本文提出了一种计算方法误差的方法。假设传感器与燃料组件表面之间的水温由核电站冷却池中燃料组件与水之间的对流换热决定。VVER-1000燃料组件表面采用具有均匀表面热流密度的垂直平板进行建模。用几何声学的近似方法描述了超声波在燃料组件表面和超声波传感器之间的介质中的传播。根据所提出的方法,数值计算的结果以图的形式执行。通过对一组计算数据的处理,得到了计算方法误差值的工程公式。所得公式已应用于核电站WWER-1000冷却池燃料组件变形监测系统的研制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
POSSIBILITY OF APPLICATION OF ZrO2-MgO-CaO CRUCIBLES FOR PRODUCING ALLOY U-10 % Zr CALCULATION ESTIMATION OF THE REQUIRED HEAT GENERATION IN TESTING FUEL ELEMENTS TO ACHIEVE SUPERCRITICAL PARAMETERS OF THE COOLANT UNDER IRRADIATION IN THE RESEARCH NUCLEAR REACTOR FEATURES OF THERMAL HYDRAULICS OF ACTIVE ZONES OF FAST LOW-POWER AND HIGH-POWER SODIUM PRODUCTION REACTORS FOR A CLOSED FUEL CYCLE SYSTEM CALCULATION OF THE STRUCTURAL MATERIALS ACTIVATION BY A FUSION NEUTRON FLUX WITH BPSD CODE HEAT PIPES IN NUCLEAR ENGINEERING
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1