Study of Analysis the Sensitivity of the Computational Environment for Radiological Research Field Size Based on Two Dimensional Dose Distribution for Water Phantom Cases

Y. Hardiyanti, Thareq Barasabha, C. Anam, N. Novitrian, F. Haryanto, A. Waris
{"title":"Study of Analysis the Sensitivity of the Computational Environment for Radiological Research Field Size Based on Two Dimensional Dose Distribution for Water Phantom Cases","authors":"Y. Hardiyanti, Thareq Barasabha, C. Anam, N. Novitrian, F. Haryanto, A. Waris","doi":"10.17140/ROJ-4-130","DOIUrl":null,"url":null,"abstract":"Purpose This study analysed the sensitivity of the field size from variations in the target volume dimensions, depth, and position. The variations in the target volume analysis were used to determine the width of the field size. Thus, the quality control of the radiation beam can be obtained. Materials and Methods The computed tomography (CT) image of the IBA Dose 1 type of water phantom consists of 350 slices. Variations in the dimension of the target volume were modelled in 10×10×10 cm3, 10×12×10 cm3 , 10.2×10×10.2 cm3, and 15×15×15 cm3. Beam parameters use one beam of irradiation on the central axis 0°, 6 MV energy, 100 cm source-skin distance (SSD), beamlet delta x, and y set to 0.1 cm. Dose distribution in the form of the XZ isodose curve and dose profile was used to observe the field size. Results In this study, the isodose curve was successfully displayed in the XZ isodose curve. The field size’s sensitivity has been successfully reviewed from variations of the target volume, depth, and position. The target X and Z direction analysis is used in determining the width and length of the field size. Conclusion The analysis related to the field size sensitivity study was obtained from a relatively valid calculation. The field size was evaluated with variations in depth of 1.5 cm, 5 cm, 10 cm, and variations in positions of 10 cm, 12 cm, 14 cm, 18 cm, and 20 cm. This study will be used as a reference to validate the distribution of computational environment for radiotherapy research (CERR) dose in the future. Thus, the accuracy of the dose calculation can be obtained.","PeriodicalId":91603,"journal":{"name":"Radiology - open journal","volume":"58 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiology - open journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17140/ROJ-4-130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose This study analysed the sensitivity of the field size from variations in the target volume dimensions, depth, and position. The variations in the target volume analysis were used to determine the width of the field size. Thus, the quality control of the radiation beam can be obtained. Materials and Methods The computed tomography (CT) image of the IBA Dose 1 type of water phantom consists of 350 slices. Variations in the dimension of the target volume were modelled in 10×10×10 cm3, 10×12×10 cm3 , 10.2×10×10.2 cm3, and 15×15×15 cm3. Beam parameters use one beam of irradiation on the central axis 0°, 6 MV energy, 100 cm source-skin distance (SSD), beamlet delta x, and y set to 0.1 cm. Dose distribution in the form of the XZ isodose curve and dose profile was used to observe the field size. Results In this study, the isodose curve was successfully displayed in the XZ isodose curve. The field size’s sensitivity has been successfully reviewed from variations of the target volume, depth, and position. The target X and Z direction analysis is used in determining the width and length of the field size. Conclusion The analysis related to the field size sensitivity study was obtained from a relatively valid calculation. The field size was evaluated with variations in depth of 1.5 cm, 5 cm, 10 cm, and variations in positions of 10 cm, 12 cm, 14 cm, 18 cm, and 20 cm. This study will be used as a reference to validate the distribution of computational environment for radiotherapy research (CERR) dose in the future. Thus, the accuracy of the dose calculation can be obtained.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于二维剂量分布的水影病例辐射研究场尺寸计算环境敏感性分析研究
目的分析靶体尺寸、深度和位置变化对靶场大小的敏感性。目标体积的变化分析用于确定场大小的宽度。从而实现对辐射光束的质量控制。材料与方法IBA剂量1型水影的CT图像由350片组成。目标体积的尺寸变化用10×10×10 cm3, 10×12×10 cm3, 10.2×10×10.2 cm3和15×15×15 cm3进行建模。光束参数采用一束辐照在中心轴上0°,6 MV能量,100 cm源肤距离(SSD),束流x和y设置为0.1 cm。剂量分布以XZ等剂量曲线和剂量分布曲线的形式来观察场的大小。结果本研究成功地将等剂量曲线显示在XZ等剂量曲线上。根据目标体积、深度和位置的变化,成功地评估了场大小的灵敏度。目标X和Z方向分析用于确定场尺寸的宽度和长度。结论野外尺寸敏感性研究的相关分析是相对有效的计算结果。以1.5 cm、5 cm、10 cm的深度变化以及10 cm、12 cm、14 cm、18 cm和20 cm的位置变化来评估田间大小。本研究将为今后验证放射研究计算环境(CERR)剂量分布提供参考。从而可以获得剂量计算的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Role of Low-Level Laser Therapy as an Adjuvant in Functional Rehabilitation of Patients with Joint Stiffness in Post-Burn Contracture Role of Digital Assessment in Wound Management Current State of Gonadal Shielding in Medical Imaging: A Review The Emergency Coil Embolization of Iatrogenic Injury to Carotid with Supraclinoid Pseudoaneurysm and Carotid Cavernous Fistula: A Case Report The Use of Lead Protection for Staff in Mobile Radiographic Settings: Can Staff Abandon Its Use?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1