{"title":"Management of Tracheal Perforation following Anterior Cervical Spine Surgery: Report of Two Cases and Review of the Literature","authors":"Xinhu Guo, H. Ji","doi":"10.1155/2022/1914642","DOIUrl":null,"url":null,"abstract":"Background Tracheal perforation is a complication very rare but challenging that follows anterior cervical spine surgery. This article describes the management of tracheal perforation due to instrument failure after anterior cervical spine surgery performed in two patients because of fracture dislocation of the subaxial cervical spine. Case Presentation. Two patients who suffered from a subaxial cervical fracture and dislocation were subjected to anterior cervical spine surgery for fracture reduction and cervical fusion. However, instrumentation failure occurred in both patients, resulting in implant displacement and penetration into the posterior tracheal wall. Revision surgery consisted of fracture reduction, multilevel posterior fixation, and removal of the displaced anterior cervical implants. Tracheal perforation was bypassed by placing a tracheostomy tube in a caudal position for the diversion of the airflow and tracheal hygiene. The thorough debridement and drainage performed in both patients allowed a complete healing of the anterior wound in both of them, with no sign of infection or subcutaneous emphysema, as confirmed by postoperative CT scan and flexible bronchoscopy. Both patients acquired a solid fusion of the cervical spine at last follow-up (16 months and 24 months). Conclusions The perforation of the trachea after anterior cervical spine surgery due to the displacement of the implants could be managed using posterior cervical instrumentation and fusion, the removal of the anterior implant, debridement and drainage, and the use of a distal bypassing tracheostomy tube.","PeriodicalId":30287,"journal":{"name":"Case Reports in Orthopedics","volume":"53 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2022-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/1914642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background Tracheal perforation is a complication very rare but challenging that follows anterior cervical spine surgery. This article describes the management of tracheal perforation due to instrument failure after anterior cervical spine surgery performed in two patients because of fracture dislocation of the subaxial cervical spine. Case Presentation. Two patients who suffered from a subaxial cervical fracture and dislocation were subjected to anterior cervical spine surgery for fracture reduction and cervical fusion. However, instrumentation failure occurred in both patients, resulting in implant displacement and penetration into the posterior tracheal wall. Revision surgery consisted of fracture reduction, multilevel posterior fixation, and removal of the displaced anterior cervical implants. Tracheal perforation was bypassed by placing a tracheostomy tube in a caudal position for the diversion of the airflow and tracheal hygiene. The thorough debridement and drainage performed in both patients allowed a complete healing of the anterior wound in both of them, with no sign of infection or subcutaneous emphysema, as confirmed by postoperative CT scan and flexible bronchoscopy. Both patients acquired a solid fusion of the cervical spine at last follow-up (16 months and 24 months). Conclusions The perforation of the trachea after anterior cervical spine surgery due to the displacement of the implants could be managed using posterior cervical instrumentation and fusion, the removal of the anterior implant, debridement and drainage, and the use of a distal bypassing tracheostomy tube.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
颈椎前路手术后气管穿孔的处理:2例报告及文献复习
背景:气管穿孔是颈椎前路手术后非常罕见但具有挑战性的并发症。本文描述了两例因颈椎下轴骨折脱位而行颈椎前路手术后器械失效导致气管穿孔的处理。案例演示。2例颈椎下轴骨折脱位患者接受颈椎前路手术进行骨折复位和颈椎融合。然而,两例患者均发生内固定失败,导致假体移位并穿透气管后壁。翻修手术包括骨折复位、多节段后路固定和移除移位的颈椎前路植入物。气管穿孔是通过放置气管造口管在尾端位置,以分流气流和气管卫生。术后CT扫描和柔性支气管镜检查证实,两例患者均进行了彻底的清创和引流,使两例患者的前部伤口完全愈合,无感染征象和皮下肺气肿。在最后一次随访(16个月和24个月)中,两例患者均获得了坚实的颈椎融合。结论颈椎前路手术后由于种植体移位引起的气管穿孔可通过后路颈椎内固定融合、取出前路种植体、清创引流及远端旁路气管造口管进行治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
55
审稿时长
14 weeks
期刊最新文献
Surgeon-Administered Ultrasound-Guided Regional Anesthesia in Fixation of Distal Fibula Fracture. Chronic Patellar Dislocation Treated With Extensive Lateral Release and Vastus Medialis Obliquus Advancement: A Case Report. Surgical Management of Complex Multiligament Knee Injury: Case Report. Surgical Technique for Removal of Old Universal Slotted AO Femoral Nail: A Case Report. Advanced Technique of Unilateral Biportal Endoscopy on Revision Surgery for Recurred Herniated Interverbral Disc: A Technical Note.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1