自動電気泳動装置(AES320)による新規セルロースアセテート膜,セレカ-VSPの臨床検査性能の評価

弘子 渡邊, 綾 杉浦, 真人 前川
{"title":"自動電気泳動装置(AES320)による新規セルロースアセテート膜,セレカ-VSPの臨床検査性能の評価","authors":"弘子 渡邊, 綾 杉浦, 真人 前川","doi":"10.2198/SBK.51.125","DOIUrl":null,"url":null,"abstract":"Serum protein fractionation has been performed by electrophoresis on cellulose acetate membrane in clinical laboratory and has been applied to diagnostic procedure for pathological states. In Japan SEPARAX-SP (Fuji film Co.) has been used as the supporting media of cellulose acetate membrane for about twenty years and will finish its production soon. A new cellulose acetate membrane, SELECA-VSP (Toyo Roshi Kaisha Ltd.) has been developed instead of SEPARAX-SP. The SELECA-VSP has almost similar features and function. In this study we evaluated quality and utility of SELECA-VSP by automated electrophoresis system (Olympus AES320). Protein fractionation using SELECA-VSP was not worse than that of SEPARAX-SP. Separation sensitivity was higher in SELECA-VSP. However, irregularly smeared bands were sometimes observed adjacent to monoclonal protein bands. Areas of each fraction are highly correlated in between SEPARAX-SP and SELECA-VSP. The fraction area of α1-globulin was significantly different in SEPARAX-SP and SELECA-VSP, and about 0.01 g / dl higher in SELECA-VSP. After the presence of the difference is recognized, automated classification system for pathological states by protein fractionation could be utilized for routine laboratory testing.In conclusion, the new cellulose acetate membrane, SELECA-VSP will replace SEPARAX-SP as electrophoretic supporting media for serum protein fractionation.","PeriodicalId":15059,"journal":{"name":"Journal of capillary electrophoresis","volume":"22 1","pages":"125-128"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of capillary electrophoresis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2198/SBK.51.125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Serum protein fractionation has been performed by electrophoresis on cellulose acetate membrane in clinical laboratory and has been applied to diagnostic procedure for pathological states. In Japan SEPARAX-SP (Fuji film Co.) has been used as the supporting media of cellulose acetate membrane for about twenty years and will finish its production soon. A new cellulose acetate membrane, SELECA-VSP (Toyo Roshi Kaisha Ltd.) has been developed instead of SEPARAX-SP. The SELECA-VSP has almost similar features and function. In this study we evaluated quality and utility of SELECA-VSP by automated electrophoresis system (Olympus AES320). Protein fractionation using SELECA-VSP was not worse than that of SEPARAX-SP. Separation sensitivity was higher in SELECA-VSP. However, irregularly smeared bands were sometimes observed adjacent to monoclonal protein bands. Areas of each fraction are highly correlated in between SEPARAX-SP and SELECA-VSP. The fraction area of α1-globulin was significantly different in SEPARAX-SP and SELECA-VSP, and about 0.01 g / dl higher in SELECA-VSP. After the presence of the difference is recognized, automated classification system for pathological states by protein fractionation could be utilized for routine laboratory testing.In conclusion, the new cellulose acetate membrane, SELECA-VSP will replace SEPARAX-SP as electrophoretic supporting media for serum protein fractionation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自动电泳装置(AES320)对新型纤维素醋酸膜celeca -VSP的临床检测性能进行评价
临床实验室已采用醋酸纤维素膜电泳分离血清蛋白,并已应用于病理状态的诊断程序。日本富士胶片公司(SEPARAX-SP)作为醋酸纤维素膜的载体已经使用了近二十年,即将完成生产。一种新的醋酸纤维素膜SELECA-VSP (Toyo Roshi Kaisha Ltd)已被开发出来取代了SEPARAX-SP。SELECA-VSP具有几乎相似的特性和功能。本研究采用自动电泳系统(Olympus AES320)评价SELECA-VSP的质量和效用。selca - vsp对蛋白质的分离效果不差于SEPARAX-SP。SELECA-VSP的分离灵敏度较高。然而,在单克隆蛋白条带附近,有时会观察到不规则的涂抹条带。每个分数的面积在SEPARAX-SP和selca - vsp之间高度相关。α1-球蛋白在SEPARAX-SP和SELECA-VSP中的分数面积差异显著,且SELECA-VSP中α1-球蛋白的分数面积高出0.01 g / dl。识别差异存在后,通过蛋白质分离的病理状态自动分类系统可用于常规实验室检测。综上所述,新型醋酸纤维素膜SELECA-VSP将取代SEPARAX-SP作为血清蛋白分离的电泳载体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electrophoretic extraction of protein complexes after separation and detection by a combined method of non-denaturing two-dimensional electrophoresis and reversible staining Use of Escherichia coli expression system for analyzing kinase motifs Proteomic analysis of spheroids of rhabdomyosarcoma cells cultured with decellularized muscle extracts Drug screening and kinase activity profiling of a novel patient-derived cell line of clear cell ovarian carcinoma Proteogenomic approach to drug targets in osteosarcomas with different original sites
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1