R.C.C. Barbosa , R.A. Silva , A.C. Lunardi , S.T.C. Silva , S.D. Corso , A.J. Fonseca , R. Stelmach , C.R.F. Carvalho
{"title":"Reproducibility, validity, and reliability of the incremental step test for subjects with moderate to severe asthma","authors":"R.C.C. Barbosa , R.A. Silva , A.C. Lunardi , S.T.C. Silva , S.D. Corso , A.J. Fonseca , R. Stelmach , C.R.F. Carvalho","doi":"10.1016/j.pulmoe.2022.02.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>We investigated the measurement properties of the incremental step test in subjects with moderate to severe asthma.</p></div><div><h3>Methods</h3><p>Subjects with moderate to severe persistent asthma were recruited from a tertiary university hospital specializing in treating severe asthma. All subjects performed one cardiopulmonary exercise test (CPET) and two incremental step tests (IST) in random sequences. Pulmonary gas exchange was measured during all exercise tests. The measurement properties investigated were reliability by intraclass correlation coefficient (ICC), measurement error by the standard error of measurement and minimum detectable difference, construct validity by Pearson's correlation, and interpretability by the ceiling and floor effects.</p></div><div><h3>Results</h3><p>Fifty subjects (38 females, mean [SD], age 43.7 [11.6] yr, % FEV<sub>1</sub> 70 [14.3], BMI 28.5 [5.3] kg/m<sup>2</sup>) completed the study. The peak oxygen uptake (peak VO<sub>2</sub>) for the CPET was 27.6 [±6.8] ml/kg/min, for the first IST was 22.3 [±5.3] ml/kg/min and for the second IST was 23.3 [±5.3] ml/kg/min. The IST presented excellent reliability (ICC=0.93, CI95% 0.88-0.96), very good measurement error (2.5%), and construct validity for peak VO<sub>2</sub> measurement compared to the CPET (<em>r</em> = 0.85; <em>p</em> < 0.001) to assess exercise capacity in subjects with moderate to severe asthma, with appropriate ceiling (10%) and floor (0%) effects.</p></div><div><h3>Conclusion</h3><p>The IST presented excellent reliability and very good measurement error and validity to assess exercise capacity in subjects with moderate to severe asthma, without ceiling or floor effects.</p></div>","PeriodicalId":54237,"journal":{"name":"Pulmonology","volume":"30 4","pages":"Pages 344-351"},"PeriodicalIF":10.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2531043722000290/pdfft?md5=3bcef3d33db67e1b3a205ce1687f7cfe&pid=1-s2.0-S2531043722000290-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulmonology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2531043722000290","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
We investigated the measurement properties of the incremental step test in subjects with moderate to severe asthma.
Methods
Subjects with moderate to severe persistent asthma were recruited from a tertiary university hospital specializing in treating severe asthma. All subjects performed one cardiopulmonary exercise test (CPET) and two incremental step tests (IST) in random sequences. Pulmonary gas exchange was measured during all exercise tests. The measurement properties investigated were reliability by intraclass correlation coefficient (ICC), measurement error by the standard error of measurement and minimum detectable difference, construct validity by Pearson's correlation, and interpretability by the ceiling and floor effects.
Results
Fifty subjects (38 females, mean [SD], age 43.7 [11.6] yr, % FEV1 70 [14.3], BMI 28.5 [5.3] kg/m2) completed the study. The peak oxygen uptake (peak VO2) for the CPET was 27.6 [±6.8] ml/kg/min, for the first IST was 22.3 [±5.3] ml/kg/min and for the second IST was 23.3 [±5.3] ml/kg/min. The IST presented excellent reliability (ICC=0.93, CI95% 0.88-0.96), very good measurement error (2.5%), and construct validity for peak VO2 measurement compared to the CPET (r = 0.85; p < 0.001) to assess exercise capacity in subjects with moderate to severe asthma, with appropriate ceiling (10%) and floor (0%) effects.
Conclusion
The IST presented excellent reliability and very good measurement error and validity to assess exercise capacity in subjects with moderate to severe asthma, without ceiling or floor effects.
PulmonologyMedicine-Pulmonary and Respiratory Medicine
CiteScore
14.30
自引率
5.10%
发文量
159
审稿时长
19 days
期刊介绍:
Pulmonology (previously Revista Portuguesa de Pneumologia) is the official journal of the Portuguese Society of Pulmonology (Sociedade Portuguesa de Pneumologia/SPP). The journal publishes 6 issues per year and focuses on respiratory system diseases in adults and clinical research. It accepts various types of articles including peer-reviewed original articles, review articles, editorials, and opinion articles. The journal is published in English and is freely accessible through its website, as well as Medline and other databases. It is indexed in Science Citation Index Expanded, Journal of Citation Reports, Index Medicus/MEDLINE, Scopus, and EMBASE/Excerpta Medica.