Validated Reversed-Phase Liquid Chromatographic Method for Simultaneous Determination of Dextromethorphan and Chlorpheniramine in Non-biological and Biological Matrices Using PDA Detector
H. Shafi, N. Din, Muhammad Imran, M. Sarwar, M. Tahir, S. Khursheed
{"title":"Validated Reversed-Phase Liquid Chromatographic Method for Simultaneous Determination of Dextromethorphan and Chlorpheniramine in Non-biological and Biological Matrices Using PDA Detector","authors":"H. Shafi, N. Din, Muhammad Imran, M. Sarwar, M. Tahir, S. Khursheed","doi":"10.4172/2153-2435.1000590","DOIUrl":null,"url":null,"abstract":"A simple, precise and sensitive reversed-phase HPLC method using Photo-diode array detector for simultaneous determination of dextromethorphan (DXM) and chlorpheniramine (CLP) in various matrices had been developed and validated. The separation was achieved within 8 minutes on a C-18 column (15 cm x 4.6 mm x 5 μm) using methanol/ pH 3.0 potassium dihydrogen phosphate buffer (60:40, v/v) mobile phase in an isocratic elution mode with flow rate 0.8 mL/min and UV-detection at 230 nm. External standard was employed for quantification. The current method demonstrated good linearity ranged 1-200 μg/mL for CLP (retention time 3.83 ± 0.10 min) with r2 of 0.9994 and 2-1000 μg/mL for DXM (retention time 5.02 ± 0.10 min) with R2 of 0.9993. The limits of detection and quantification were 0.25 μg/mL and 1.0 μg/mL for CLP and 0.50 μg/mL and 1.5 μg/mL for DXM. No interference from matrices was observed and samples remained stable in the HPLC injector for 12 h. The developed method was accurate that employed a simple liquid/liquid extraction procedure with recovery ranged 90.0%-101.9% for both analytes. Intra and inter-day precision were less than 2.5%. The method was proved robust and reproducible that is applicable to pharmaceutical (active raw materials, syrups) and biological (blood) matrices.","PeriodicalId":19833,"journal":{"name":"Pharmaceutica Analytica Acta","volume":"239 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutica Analytica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2153-2435.1000590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
A simple, precise and sensitive reversed-phase HPLC method using Photo-diode array detector for simultaneous determination of dextromethorphan (DXM) and chlorpheniramine (CLP) in various matrices had been developed and validated. The separation was achieved within 8 minutes on a C-18 column (15 cm x 4.6 mm x 5 μm) using methanol/ pH 3.0 potassium dihydrogen phosphate buffer (60:40, v/v) mobile phase in an isocratic elution mode with flow rate 0.8 mL/min and UV-detection at 230 nm. External standard was employed for quantification. The current method demonstrated good linearity ranged 1-200 μg/mL for CLP (retention time 3.83 ± 0.10 min) with r2 of 0.9994 and 2-1000 μg/mL for DXM (retention time 5.02 ± 0.10 min) with R2 of 0.9993. The limits of detection and quantification were 0.25 μg/mL and 1.0 μg/mL for CLP and 0.50 μg/mL and 1.5 μg/mL for DXM. No interference from matrices was observed and samples remained stable in the HPLC injector for 12 h. The developed method was accurate that employed a simple liquid/liquid extraction procedure with recovery ranged 90.0%-101.9% for both analytes. Intra and inter-day precision were less than 2.5%. The method was proved robust and reproducible that is applicable to pharmaceutical (active raw materials, syrups) and biological (blood) matrices.