{"title":"Effects of canal enlargement and irrigation needle depth on the cleaning of the root canal system at 3 mm from the apex","authors":"Ho-Jin Moon, C. Hong","doi":"10.5395/RDE.2012.37.1.24","DOIUrl":null,"url":null,"abstract":"Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of , , , were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.","PeriodicalId":21126,"journal":{"name":"Restorative Dentistry and Endodontics","volume":"718 1","pages":"24-28"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restorative Dentistry and Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5395/RDE.2012.37.1.24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of , , , were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.
目的:本研究的目的是验证一个假设,即灌溉去除根管系统根尖三分之一涂抹层的有效性取决于灌溉针在根管中放置的深度和根管的扩大程度。材料与方法:将80个健全的人下切牙按放大尺寸(25、30、35、40)和入针深度(距工作长度3 mm, WL-3 mm和距工作长度9 mm, WL-9 mm)分为8组。采用Profile.06旋转镍钛锉将各管扩大至工作长度,并用5.25%的NaOCl灌水。然后,每根管最后用3 mL 3% EDTA冲洗4分钟,然后用5 mL 5.25% NaOCl按工作长度不同的水平(WL-3 mm和WL-9 mm)冲洗。每个样品都准备好进行扫描电子显微镜(SEM)。从每根根管的根尖狭窄处取3mm的照片,放大倍数为,,用于最后的评估。结果:当根管扩大到30 #以上时,WL-3 mm组去除涂抹层的效果有显著差异。针入深度WL-3 mm与WL-9 mm去除根尖涂抹层差异有统计学意义。结论:根尖预备至#35/40 06锥形锉,根管针尖距工作长度3mm,有效地完成了根管根尖部分涂片层的去除。