Akash Chaurasia, Jerry Yan, Robert Li, Kate McCarren, Claire State, Hannah Takasuka, Evan Bender, Aditi Jithendra, Julius K Oni, Amir Manbachi
{"title":"An Evaluation of Sensing Technologies to Measure Intraoperative Leg Length for Total Hip Arthroplasty.","authors":"Akash Chaurasia, Jerry Yan, Robert Li, Kate McCarren, Claire State, Hannah Takasuka, Evan Bender, Aditi Jithendra, Julius K Oni, Amir Manbachi","doi":"10.1115/dmd2020-9056","DOIUrl":null,"url":null,"abstract":"<p><p>Total hip arthroplasty (THA) procedures have been identified as high-volume procedures with growing prevalence. During the procedure, orthopedic surgeons largely rely solely on qualitative assessment to ensure an excessive limb length discrepancy (LLD) is not introduced from the implant selection. LLD can result in back pain and gait complications, with some cases of LLD requiring a revision procedure to mitigate. To address this issue, we evaluated several methods of sensing distance intraoperatively to determine the best approach to measure leg length during the THA procedure. A testing setup using a sawbones model of hip anatomy in the decubitus position was used as a simulation of the THA procedure to test the accuracy of each of the sensing modalities.</p>","PeriodicalId":20926,"journal":{"name":"Quaternary Science Reviews","volume":"131 1","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8895228/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quaternary Science Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2020-9056","RegionNum":1,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/7/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"GEOGRAPHY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Total hip arthroplasty (THA) procedures have been identified as high-volume procedures with growing prevalence. During the procedure, orthopedic surgeons largely rely solely on qualitative assessment to ensure an excessive limb length discrepancy (LLD) is not introduced from the implant selection. LLD can result in back pain and gait complications, with some cases of LLD requiring a revision procedure to mitigate. To address this issue, we evaluated several methods of sensing distance intraoperatively to determine the best approach to measure leg length during the THA procedure. A testing setup using a sawbones model of hip anatomy in the decubitus position was used as a simulation of the THA procedure to test the accuracy of each of the sensing modalities.
期刊介绍:
Quaternary Science Reviews caters for all aspects of Quaternary science, and includes, for example, geology, geomorphology, geography, archaeology, soil science, palaeobotany, palaeontology, palaeoclimatology and the full range of applicable dating methods. The dividing line between what constitutes the review paper and one which contains new original data is not easy to establish, so QSR also publishes papers with new data especially if these perform a review function. All the Quaternary sciences are changing rapidly and subject to re-evaluation as the pace of discovery quickens; thus the diverse but comprehensive role of Quaternary Science Reviews keeps readers abreast of the wider issues relating to new developments in the field.