{"title":"Influencia de la incorporación de la tomosíntesis en un centro de diagnóstico mamario.","authors":"G. Febles, Cristina Balbiani, Graciela Vázquez","doi":"10.29193/rmu.37.3.5","DOIUrl":null,"url":null,"abstract":"Introduction: significant technological progress has been made in the history of mammography. Recently, direct digital mammography plus tomosynthesis arrived and improved breast cancer screening.Objective: to evaluate the effects of new technology in the performance of mammography, at the Breast Diagnostic Service of the British Hospital.Method: mammography performance during 2019- 2020 was compared to that between 2010 and 2018.In 2019 the previous tehcnology was substituted by a direct digital mammogram with tomosynthesis, Hologic, Selenia Dimensions model.Results: 10.725 mammographies were done in 2019-2020. Cancer was detected in 84 cases and the cancer detection rate was 8 per 1000 persons. PPV was 35%. 45.438 mammographies were done in 2010-2018. Cancer was detected in 229 cases and the cancer detection rate was 5 per 1.000 persons. PPV was 40%. As to images, it is worth pointing out an increase in microcalcifications between 2019 and 2020, when they grew from 7% of cases to 19% of cases and distortions increased from 11% to 13%.DCIS was 4 times greater in 2019-2020 when compare to the previous period of time (17% of all detected cases).Conclusions: the integration of tomosynthesis increased 60% the cancer detection rate and the DCIS was 4 times greater.","PeriodicalId":51931,"journal":{"name":"Revista Medica del Uruguay","volume":"20 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2021-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Medica del Uruguay","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29193/rmu.37.3.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: significant technological progress has been made in the history of mammography. Recently, direct digital mammography plus tomosynthesis arrived and improved breast cancer screening.Objective: to evaluate the effects of new technology in the performance of mammography, at the Breast Diagnostic Service of the British Hospital.Method: mammography performance during 2019- 2020 was compared to that between 2010 and 2018.In 2019 the previous tehcnology was substituted by a direct digital mammogram with tomosynthesis, Hologic, Selenia Dimensions model.Results: 10.725 mammographies were done in 2019-2020. Cancer was detected in 84 cases and the cancer detection rate was 8 per 1000 persons. PPV was 35%. 45.438 mammographies were done in 2010-2018. Cancer was detected in 229 cases and the cancer detection rate was 5 per 1.000 persons. PPV was 40%. As to images, it is worth pointing out an increase in microcalcifications between 2019 and 2020, when they grew from 7% of cases to 19% of cases and distortions increased from 11% to 13%.DCIS was 4 times greater in 2019-2020 when compare to the previous period of time (17% of all detected cases).Conclusions: the integration of tomosynthesis increased 60% the cancer detection rate and the DCIS was 4 times greater.