Yafei Yang, Guo-Zhen Wang, Li Wang, Yinsheng Chen, Zhizheng Shen
{"title":"Study on the influence of different factors on linear CCD online detection device for drug mixing concentration","authors":"Yafei Yang, Guo-Zhen Wang, Li Wang, Yinsheng Chen, Zhizheng Shen","doi":"10.3233/jcm-226670","DOIUrl":null,"url":null,"abstract":"In this experiment, the linear CCD mixing concentration online detection device was studied under five concentrations of carmine solution: 0.1 g/L, 0.3 g/L, 0.5 g/L, 0.7 g/L, and 0.9 g/L, for the factors that can affect the detection accuracy in the real spraying process (spray flow rate, spray pressure, liquid temperature, and light intensity). The results show the following results: different spray flow rates have less influence on the concentration detection results; the greater the concentration of the solution, the less the influence of the spray pressure on the detection; the smaller the concentration of the solution, the greater the influence of the spray pressure on the detection; the greater the concentration of the solution, the greater the influence of the liquid temperature on the detection; the smaller the concentration of the solution, the greater the influence of the liquid temperature on the detection; the smaller the concentration of the solution, the greater the influence of the liquid less.","PeriodicalId":14668,"journal":{"name":"J. Comput. Methods Sci. Eng.","volume":"68 1","pages":"1719-1730"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Comput. Methods Sci. Eng.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/jcm-226670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this experiment, the linear CCD mixing concentration online detection device was studied under five concentrations of carmine solution: 0.1 g/L, 0.3 g/L, 0.5 g/L, 0.7 g/L, and 0.9 g/L, for the factors that can affect the detection accuracy in the real spraying process (spray flow rate, spray pressure, liquid temperature, and light intensity). The results show the following results: different spray flow rates have less influence on the concentration detection results; the greater the concentration of the solution, the less the influence of the spray pressure on the detection; the smaller the concentration of the solution, the greater the influence of the spray pressure on the detection; the greater the concentration of the solution, the greater the influence of the liquid temperature on the detection; the smaller the concentration of the solution, the greater the influence of the liquid temperature on the detection; the smaller the concentration of the solution, the greater the influence of the liquid less.