{"title":"StatCom control for voltage stability improvement at a fixed speed wind farm under unbalanced faults","authors":"M. Vimalraj, B. Alex, M. Tamilarasi","doi":"10.1109/ICICES.2014.7034140","DOIUrl":null,"url":null,"abstract":"In this paper investigations on a fixed speed wind farm with squirrel cage induction generators directly connected to the grid in combination with a StatCom under unbalanced grid voltage fault are given by means of theory and simulations. The stability of fixed speed wind turbines can be improved by a StatCom, which is well known and documented in literature for balanced grid voltage dips. Under unbalanced grid voltage dips the negative sequence voltage causes additional generator torque oscillations. A StatCom control structure with the capability to control the positive or negative sequence of the voltage is used. The simulation results clarify the effect of positive and negative sequence voltage compensation by a StatCom on the operation of a fixed speed wind farm. The influence of different StatCom control targets is investigated that lead to an increased network voltage stability and lower torque pulsations.","PeriodicalId":13713,"journal":{"name":"International Conference on Information Communication and Embedded Systems (ICICES2014)","volume":"247 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Information Communication and Embedded Systems (ICICES2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICES.2014.7034140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
In this paper investigations on a fixed speed wind farm with squirrel cage induction generators directly connected to the grid in combination with a StatCom under unbalanced grid voltage fault are given by means of theory and simulations. The stability of fixed speed wind turbines can be improved by a StatCom, which is well known and documented in literature for balanced grid voltage dips. Under unbalanced grid voltage dips the negative sequence voltage causes additional generator torque oscillations. A StatCom control structure with the capability to control the positive or negative sequence of the voltage is used. The simulation results clarify the effect of positive and negative sequence voltage compensation by a StatCom on the operation of a fixed speed wind farm. The influence of different StatCom control targets is investigated that lead to an increased network voltage stability and lower torque pulsations.