Regular replacement of daily wear rigidgas-permeable contact lenses

Bsc, MCOptom, DCLP Craig A. Woods, BSc, PhD, DSc, MCOptom, FVCO, FARO Nathan Efron
{"title":"Regular replacement of daily wear rigidgas-permeable contact lenses","authors":"Bsc, MCOptom, DCLP Craig A. Woods,&nbsp;BSc, PhD, DSc, MCOptom, FVCO, FARO Nathan Efron","doi":"10.1016/S0141-7037(96)80041-3","DOIUrl":null,"url":null,"abstract":"<div><p>A prospective, single-centre, controlled, double-masked randomised study was conducted to determine the benefits, ifany, of regular replacement of daily-wear rigid gas permeable (RGP) contact lenses. Forty-one subjects, divided into two groups, wore Quantum 2 lenses (Bausch &amp; Lomb, Rochester, New York, USA; <em>Dk=120</em>) for 12 months on a daily-wear basis; subjects in group I replaced lenses every 3 months, whereas those in group II were not scheduled to replace lenses. All subjects were existing RGP lens wearers without any contact lens-induced pathology (&gt;grade 1). The integrity of the lenses and the ocular responses to lens wear were monitored in both groups every 3 months. Compared with lenses worn by subjects in group II, lenses worn by subjects in group I displayed significantly less surface drying (at 9 months), less mucus coating (at 12 months), less surface deposition (at 12 months), and less surface scratching (at 9 and 12 months) (p 0.05, ANOVA). Compared with the ocular response of subjects in group II, the ocular response of subjects in group I displayed significantly less corneal staining at 12 months (p&lt;0.05,- ANOVA). No significant differences between the groups were observed with respect to comfort, vision, or any of the other variables assessed. We advocate that, in order to maintain optimal lens integrity and ocular health, RGP lenses used for daily wear should be replaced every 6 months.</p></div>","PeriodicalId":100842,"journal":{"name":"Journal of The British Contact Lens Association","volume":"19 3","pages":"Pages 83-89"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0141-7037(96)80041-3","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The British Contact Lens Association","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141703796800413","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

A prospective, single-centre, controlled, double-masked randomised study was conducted to determine the benefits, ifany, of regular replacement of daily-wear rigid gas permeable (RGP) contact lenses. Forty-one subjects, divided into two groups, wore Quantum 2 lenses (Bausch & Lomb, Rochester, New York, USA; Dk=120) for 12 months on a daily-wear basis; subjects in group I replaced lenses every 3 months, whereas those in group II were not scheduled to replace lenses. All subjects were existing RGP lens wearers without any contact lens-induced pathology (>grade 1). The integrity of the lenses and the ocular responses to lens wear were monitored in both groups every 3 months. Compared with lenses worn by subjects in group II, lenses worn by subjects in group I displayed significantly less surface drying (at 9 months), less mucus coating (at 12 months), less surface deposition (at 12 months), and less surface scratching (at 9 and 12 months) (p 0.05, ANOVA). Compared with the ocular response of subjects in group II, the ocular response of subjects in group I displayed significantly less corneal staining at 12 months (p<0.05,- ANOVA). No significant differences between the groups were observed with respect to comfort, vision, or any of the other variables assessed. We advocate that, in order to maintain optimal lens integrity and ocular health, RGP lenses used for daily wear should be replaced every 6 months.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
定期更换日常佩戴的硬性透气性隐形眼镜
进行了一项前瞻性、单中心、对照、双盲随机研究,以确定定期更换日常佩戴的硬性透气性(RGP)隐形眼镜的益处。41名受试者被分成两组,佩戴Quantum 2隐形眼镜(Bausch &朗姆,罗切斯特,纽约,美国;Dk=120),每天佩戴12个月;第一组每3个月更换一次隐形眼镜,而第二组不定期更换隐形眼镜。所有受试者均为现有的RGP隐形眼镜佩戴者,无任何隐形眼镜引起的病理(> 1级)。两组患者每3个月监测一次隐形眼镜的完整性和对隐形眼镜佩戴的眼部反应。与II组受试者佩戴的镜片相比,I组受试者佩戴的镜片表面干燥(9个月时)、黏液涂层(12个月时)、表面沉积(12个月时)和表面划伤(9个月和12个月时)明显减少(p 0.05,方差分析)。与II组相比,I组受试者的眼反应在12个月时角膜染色明显减少(p < 0.05,-方差分析)。两组之间在舒适度、视力或任何其他评估变量方面没有观察到显著差异。我们建议,为了保持最佳的晶状体完整性和眼部健康,日常佩戴的RGP镜片应每6个月更换一次。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Announcement Editorial Editorial Board Editorial Notices
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1