J.E. Bateman, J.F. Connolly, R. Stephenson, G.J. Tappern, A.C. Flesher
{"title":"The Rutherford Appleton laboratory's mark I multiwire proportional counter positron camera","authors":"J.E. Bateman, J.F. Connolly, R. Stephenson, G.J. Tappern, A.C. Flesher","doi":"10.1016/0167-5087(84)91359-0","DOIUrl":null,"url":null,"abstract":"<div><p>A small (30 cm × 30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes (<sup>15</sup>O, <sup>11</sup>C, <sup>18</sup>F, <sup>124</sup>I) and available isotopic generator systems (<sup>82</sup>Rb, <sup>68</sup>Ga). At RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 1","pages":"Pages 209-231"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)91359-0","citationCount":"36","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784913590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 36
Abstract
A small (30 cm × 30 cm) model of a proposed large aperture positron camera has been developed at Rutherford Appleton Laboratory. Based on multiwire proportional counter technology it uses lead foil cathodes which function simultaneously as converters for the 511 keV gamma rays and readout electrodes for a delay line readout system. The detectors have been built up into a portable imaging system complete with a dedicated computer for data taking, processing and display. This has permitted evaluation of this type of positron imaging system in the clinical environment using both cyclotron generated isotopes (15O, 11C, 18F, 124I) and available isotopic generator systems (82Rb, 68Ga). At RAL we provided a complete hardware system and sufficient software to permit our hospital based colleagues to generate useful images with the minimum of effort. A complete description of the system is given with performance figures and some of the images obtained in three hospital visits are presented. Some detailed studies of the imaging performance of the positron camera are reported which have bearing on the design of future, improved systems.