Comparison of Intraocular Pressure between Air Puff Tonometer and Goldmann Applanation Tonometer at a Tertiary Eye Care Centre

Akbar Umme Salma
{"title":"Comparison of Intraocular Pressure between Air Puff Tonometer and Goldmann Applanation Tonometer at a Tertiary Eye Care Centre","authors":"Akbar Umme Salma","doi":"10.23880/oajo-16000236","DOIUrl":null,"url":null,"abstract":"Purpose: The purpose of this study was to evaluate the role of air puff (AP) tonometer by comparing the measurements of intraocular pressure (IOP) made using this device with those made using a Goldmann applanation tonometer (GAT) at Chittagong Eye Infirmary and Training Complex. Method: An observational and comparative study was carried out at Chittagong Eye Infirmary and Training Complex from January 2016 to January 2017. Two techniques for IOP measurements using the standard GAT and the non-contact tonometer (NCT) were compared. A total of 400 eyes from 200 patients were included in the study. Results: The mean IOP as measured by GAT in the right eye was 14.50±5.59mmHg and in the left eye was 14.87±7.03mmHg while that as measured by NCT in the right eye was 15.97±6.12mmHg and in the left eye was 15.94±6.98mmHg. The mean difference between the two methods of measurement in the right eye was 1.47±0.53mmHg and the left eye was 1.07±0.05mmHg. The readings obtained by NCT were higher than those obtained by GAT. There was no statistically significant difference found in IOP measurements between GAT and NCT according to patient’s age, gender or laterality of eyes. Conclusion: There was a significant difference in the measurement of IOP between GAT and NCT. Goldmann applanation tonometry remains the most suitable and reliable method for measuring IOP.","PeriodicalId":91939,"journal":{"name":"Open access journal of ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open access journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/oajo-16000236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this study was to evaluate the role of air puff (AP) tonometer by comparing the measurements of intraocular pressure (IOP) made using this device with those made using a Goldmann applanation tonometer (GAT) at Chittagong Eye Infirmary and Training Complex. Method: An observational and comparative study was carried out at Chittagong Eye Infirmary and Training Complex from January 2016 to January 2017. Two techniques for IOP measurements using the standard GAT and the non-contact tonometer (NCT) were compared. A total of 400 eyes from 200 patients were included in the study. Results: The mean IOP as measured by GAT in the right eye was 14.50±5.59mmHg and in the left eye was 14.87±7.03mmHg while that as measured by NCT in the right eye was 15.97±6.12mmHg and in the left eye was 15.94±6.98mmHg. The mean difference between the two methods of measurement in the right eye was 1.47±0.53mmHg and the left eye was 1.07±0.05mmHg. The readings obtained by NCT were higher than those obtained by GAT. There was no statistically significant difference found in IOP measurements between GAT and NCT according to patient’s age, gender or laterality of eyes. Conclusion: There was a significant difference in the measurement of IOP between GAT and NCT. Goldmann applanation tonometry remains the most suitable and reliable method for measuring IOP.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
某三级眼科保健中心气肿眼压计与Goldmann压平眼压计眼压的比较
目的:本研究的目的是通过比较在吉大港眼科医院和训练中心使用充气眼压计(AP)测量的眼压(IOP)和使用Goldmann压眼压计(GAT)测量的眼压来评估充气眼压计的作用。方法:2016年1月至2017年1月在吉大港眼科医院和培训中心进行观察和比较研究。比较了使用标准GAT和非接触式眼压计(NCT)测量眼压的两种技术。来自200名患者的400只眼睛被纳入了这项研究。结果:GAT测得右眼平均IOP为14.50±5.59mmHg,左眼平均IOP为14.87±7.03mmHg; NCT测得右眼平均IOP为15.97±6.12mmHg,左眼平均IOP为15.94±6.98mmHg。右眼和左眼两种测量方法的平均差值分别为1.47±0.53mmHg和1.07±0.05mmHg。NCT获得的读数高于GAT获得的读数。GAT和NCT在IOP测量上根据患者的年龄、性别和眼侧度没有统计学差异。结论:GAT与NCT在眼压测量上有显著性差异。Goldmann压扁眼压计仍然是测量眼压最合适和可靠的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Clinical Outcomes of Nd: YAG Laser Posterior Capsulotomy: Impact on Intraocular Pressure, Refraction, Anterior Chamber Depth, and Macular Thickness Psychological Wellbeing in Patients with Glaucoma: A Newer Perspective in Glaucoma Management Elevated Serum Hydrogen Sulfide in Age Related Macular Degeneration Modified Samuel Masket’s Technique Non-Surgical Pneumatic Repair of Stage 2 Macular Holes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1