{"title":"The Influence of CaCl2-Blended Acrylic Polymer on Steel Rebar Corrosion and Acid Attack Resistance of Mortar","authors":"O. Onuaguluchi, N. Banthia","doi":"10.3390/cmd3010009","DOIUrl":null,"url":null,"abstract":"A realistic forecast of the impact of CaCl2-blended acrylic polymer (CP) emulsions on steel reinforcement corrosion is difficult without a detailed study. This is traceable to the conflicting effects of cement additives on the chloride threshold value, pore solution chemistry, and matrix resistivity. Hence, in the study reported herein, the actual influence of 0.5–1.5 wt% CP on rebar corrosion was assessed via an accelerated corrosion test. The macrocell current, half-cell potential measurements (HCP), reinforcement cover crack propagation, and rebar deterioration were monitored. The resistance of mortar specimens to acid-induced degradation was also evaluated over time. The corrosion test results indicate that steel rebar corrosion initiation in the mortar expedited as the CP dosage in mixtures increased. Consequently, the time required for the CP-modified specimens to crack shortened. Moreover, non-uniform rebar section loss and surface crack width widening were also observed in CP-modified mortar specimens. However, X-ray diffraction (XRD) analyses of the plain Ref and 1.5% CP corrosion byproduct residues indicated that key phases such as akaganeite, goethite, lepidocrocite, hematite, and magnetite were quantitatively similar. Interestingly, the addition of 1.0–1.5% CP to mixtures enhanced the acid attack resistance of mortars. For now, these results indicate that CP should only be used as a chemical admixture in unreinforced cement composites.","PeriodicalId":10693,"journal":{"name":"Corrosion and Materials Degradation","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Corrosion and Materials Degradation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/cmd3010009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A realistic forecast of the impact of CaCl2-blended acrylic polymer (CP) emulsions on steel reinforcement corrosion is difficult without a detailed study. This is traceable to the conflicting effects of cement additives on the chloride threshold value, pore solution chemistry, and matrix resistivity. Hence, in the study reported herein, the actual influence of 0.5–1.5 wt% CP on rebar corrosion was assessed via an accelerated corrosion test. The macrocell current, half-cell potential measurements (HCP), reinforcement cover crack propagation, and rebar deterioration were monitored. The resistance of mortar specimens to acid-induced degradation was also evaluated over time. The corrosion test results indicate that steel rebar corrosion initiation in the mortar expedited as the CP dosage in mixtures increased. Consequently, the time required for the CP-modified specimens to crack shortened. Moreover, non-uniform rebar section loss and surface crack width widening were also observed in CP-modified mortar specimens. However, X-ray diffraction (XRD) analyses of the plain Ref and 1.5% CP corrosion byproduct residues indicated that key phases such as akaganeite, goethite, lepidocrocite, hematite, and magnetite were quantitatively similar. Interestingly, the addition of 1.0–1.5% CP to mixtures enhanced the acid attack resistance of mortars. For now, these results indicate that CP should only be used as a chemical admixture in unreinforced cement composites.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
cacl2 -混配丙烯酸聚合物对钢筋腐蚀及砂浆抗酸蚀性能的影响
如果没有详细的研究,很难对cacl2 -共混丙烯酸聚合物(CP)乳液对钢筋腐蚀的影响进行现实的预测。这可以追溯到水泥添加剂对氯化物阈值、孔隙溶液化学和基质电阻率的相互冲突的影响。因此,在本文报道的研究中,通过加速腐蚀试验评估了0.5-1.5 wt% CP对钢筋腐蚀的实际影响。监测了大胞电流、半胞电位测量(HCP)、钢筋覆盖裂纹扩展和钢筋劣化情况。随着时间的推移,砂浆试样对酸诱导降解的抵抗力也进行了评估。腐蚀试验结果表明,随着CP掺量的增加,砂浆中钢筋的腐蚀起始速度加快。因此,cp改性试样的开裂时间缩短。此外,cp改性砂浆试件的钢筋截面损失不均匀,表面裂缝宽度扩大。然而,对普通Ref和1.5% CP腐蚀副产物残留物的x射线衍射(XRD)分析表明,关键相如赤铁矿、针铁矿、绢云母、赤铁矿和磁铁矿在数量上是相似的。有趣的是,在混合物中添加1.0-1.5% CP可以增强砂浆的抗酸侵蚀性能。目前,这些结果表明CP只能作为非增强水泥复合材料的化学外加剂使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
0.00%
发文量
0
期刊最新文献
Influence of Isothermal Annealing in the 600 to 750 °C Range on the Degradation of SAF 2205 Duplex Stainless Steel Unraveling the Corrosion of the Ti–6Al–4V Orthopedic Alloy in Phosphate-Buffered Saline (PBS) Solution: Influence of Frequency and Potential Impact of the Delay Period between Electrochemical Hydrogen Charging and Tensile Testing on the Mechanical Properties of Mild Steel Mechanistic Analysis of Hydrogen Evolution Reaction on Stationary Polycrystalline Gold Electrodes in H2SO4 Solutions In-Situ AFM Studies of Surfactant Adsorption on Stainless Steel Surfaces during Electrochemical Polarization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1