Simulated airway drills as a tool to measure and guide improvements in endotracheal intubation preparation in the paediatric emergency department.

IF 1.1 Q2 Social Sciences BMJ Simulation & Technology Enhanced Learning Pub Date : 2021-06-04 eCollection Date: 2021-01-01 DOI:10.1136/bmjstel-2020-000810
Kei U Wong, Isabel Gross, Beth L Emerson, Michael P Goldman
{"title":"Simulated airway drills as a tool to measure and guide improvements in endotracheal intubation preparation in the paediatric emergency department.","authors":"Kei U Wong, Isabel Gross, Beth L Emerson, Michael P Goldman","doi":"10.1136/bmjstel-2020-000810","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Emergent paediatric intubation is an infrequent but high-stakes procedure in the paediatric emergency department (PED). Successful intubations depend on efficient and accurate preparation. The aim of this study was to use airway drills (brief in-situ simulations) to identify gaps in our paediatric endotracheal intubation preparation process, to improve on our process and to demonstrate sustainability of these improvements over time in a new staff cohort.</p><p><strong>Method: </strong>This was a single-centre, simulation-based improvement study. Baseline simulated airway drills were used to identify barriers in our airway preparation process. Drills were scored for time and accuracy on an iteratively developed 16-item rubric. Interventions were identified and their impact was measured using simulated airway drills. Statistical analysis was performed using unpaired t-tests between the three data collection periods.</p><p><strong>Results: </strong>Twenty-five simulated airway drills identified gaps in our airway preparation process and served as our baseline performance. The main problem identified was that staff members had difficulty locating essential airway equipment. Therefore, we optimised and implemented a weight-based airway cart. We demonstrated significant improvement and sustainability in the accuracy of obtaining essential airway equipment from baseline to postintervention (62% vs 74%; p=0.014), and postintervention to sustainability periods (74% vs 77%; p=0.573). Similarly, we decreased and sustained the time (in seconds) required to prepare for a paediatric intubation from baseline to postintervention (173 vs 109; p=0.001) and postintervention to sustainability (109 vs 103; p=0.576).</p><p><strong>Conclusions: </strong>Simulated airway drills can be used as a tool to identify process gaps, measure and improve paediatric intubation readiness.</p>","PeriodicalId":44757,"journal":{"name":"BMJ Simulation & Technology Enhanced Learning","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2021-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8936761/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Simulation & Technology Enhanced Learning","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bmjstel-2020-000810","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Social Sciences","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Emergent paediatric intubation is an infrequent but high-stakes procedure in the paediatric emergency department (PED). Successful intubations depend on efficient and accurate preparation. The aim of this study was to use airway drills (brief in-situ simulations) to identify gaps in our paediatric endotracheal intubation preparation process, to improve on our process and to demonstrate sustainability of these improvements over time in a new staff cohort.

Method: This was a single-centre, simulation-based improvement study. Baseline simulated airway drills were used to identify barriers in our airway preparation process. Drills were scored for time and accuracy on an iteratively developed 16-item rubric. Interventions were identified and their impact was measured using simulated airway drills. Statistical analysis was performed using unpaired t-tests between the three data collection periods.

Results: Twenty-five simulated airway drills identified gaps in our airway preparation process and served as our baseline performance. The main problem identified was that staff members had difficulty locating essential airway equipment. Therefore, we optimised and implemented a weight-based airway cart. We demonstrated significant improvement and sustainability in the accuracy of obtaining essential airway equipment from baseline to postintervention (62% vs 74%; p=0.014), and postintervention to sustainability periods (74% vs 77%; p=0.573). Similarly, we decreased and sustained the time (in seconds) required to prepare for a paediatric intubation from baseline to postintervention (173 vs 109; p=0.001) and postintervention to sustainability (109 vs 103; p=0.576).

Conclusions: Simulated airway drills can be used as a tool to identify process gaps, measure and improve paediatric intubation readiness.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
将模拟气道演练作为衡量和指导儿科急诊室改进气管插管准备工作的工具。
导言:儿科急诊插管是儿科急诊室(PED)中一种并不常见但风险极高的手术。成功的插管取决于高效、准确的准备。本研究的目的是利用气道演练(简短的现场模拟)找出儿科气管插管准备过程中的不足之处,改进我们的流程,并在新的员工队伍中证明这些改进在一段时间内的可持续性:这是一项基于模拟的单中心改进研究。方法:这是一项以模拟为基础的单中心改进研究。通过模拟气道演练来确定气道准备过程中的障碍。根据反复制定的 16 项评分标准,对演练的时间和准确性进行评分。通过模拟气道演练确定干预措施并衡量其效果。在三个数据收集期之间使用非配对 t 检验进行统计分析:25 次模拟气道演练找出了我们在气道准备过程中存在的不足,并作为我们的基线绩效。发现的主要问题是工作人员难以找到必要的气道设备。因此,我们优化并实施了基于重量的气道推车。从基线到干预后(62% vs 74%; p=0.014),以及从干预后到持续期间(74% vs 77%; p=0.573),我们在获取必要气道设备的准确性方面都有了明显改善和持续提高。同样,从基线到干预后(173 vs 109;p=0.001)以及干预后到持续期(109 vs 103;p=0.576),我们减少并保持了儿科插管准备所需的时间(秒):模拟气道演练可作为一种工具,用于识别流程差距、衡量和改进儿科插管准备情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMJ Simulation & Technology Enhanced Learning
BMJ Simulation & Technology Enhanced Learning HEALTH CARE SCIENCES & SERVICES-
自引率
0.00%
发文量
0
期刊最新文献
Influence of Simulation-based Training on Reflective Practice. Virtual tabletop simulations for primary care pandemic preparedness and response. Developing a simulation programme to train airway management during the COVID-19 pandemic in a tertiary-level hospital. Interprofessional teamwork for managing medical deterioration in pregnancy: what contributes to good clinical performance in simulated practice? Age suit simulation replicates in healthy young adults the functional challenges to balance experienced by older adults: an observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1