{"title":"Energy efficiency using Distributed Generation; Cafeteria of Engineer Faculty Campeche, Mexico","authors":"Jorge J. Chan-Gonzalez, Isaac A. Saravia-Pérez, F. Lezama-Zarraga, Meng Yen Shih","doi":"10.35429/jrd.2021.20.7.1.12","DOIUrl":null,"url":null,"abstract":"In the present work, an integral design of the cafeteria located at Faculty of Engineering of Autonomous University of Campeche is carried out. Four scenarios of Photo Voltaic (PV) generation have been studied. A 14 PV modules arrangement of 440 each, with azimuthal angle of 180º and a slope angle of 15º; the other is similar to the previous, but the slope angle was 19.85º. The following was a 24 PV modules arrangement of 440, with an azimuthal angle of 218º and a slope angle of 15º. The last arrangement consists of 24 PV modules arrangement of 440, with azimuthal angle of 218º and a slope angle of 19.85º. Where all of them are associated with the economic aspect to obtain greater efficiency of the plant with minimum recovery time. The free software System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL) has been employed. Complete seasonal analysis has also been performed considering Gran Demanda Media Ordinaria en México (GDMO de CFE in Mexico) within the period January 2020 to March 2021. The best results are energy generation 17,570 kWh. Capacity factor 19%. Energy performance 1,671 kWh/kW. Performance relation 0.74. Leveled cost 5.39 ¢/kWh. And return on investment in 0.6 years. The GD-PV plant prevents the emission into the atmosphere of 778.85 kg of CO2 equivalent.","PeriodicalId":55034,"journal":{"name":"IBM Journal of Research and Development","volume":"34 1","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IBM Journal of Research and Development","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.35429/jrd.2021.20.7.1.12","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 0

Abstract

In the present work, an integral design of the cafeteria located at Faculty of Engineering of Autonomous University of Campeche is carried out. Four scenarios of Photo Voltaic (PV) generation have been studied. A 14 PV modules arrangement of 440 each, with azimuthal angle of 180º and a slope angle of 15º; the other is similar to the previous, but the slope angle was 19.85º. The following was a 24 PV modules arrangement of 440, with an azimuthal angle of 218º and a slope angle of 15º. The last arrangement consists of 24 PV modules arrangement of 440, with azimuthal angle of 218º and a slope angle of 19.85º. Where all of them are associated with the economic aspect to obtain greater efficiency of the plant with minimum recovery time. The free software System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL) has been employed. Complete seasonal analysis has also been performed considering Gran Demanda Media Ordinaria en México (GDMO de CFE in Mexico) within the period January 2020 to March 2021. The best results are energy generation 17,570 kWh. Capacity factor 19%. Energy performance 1,671 kWh/kW. Performance relation 0.74. Leveled cost 5.39 ¢/kWh. And return on investment in 0.6 years. The GD-PV plant prevents the emission into the atmosphere of 778.85 kg of CO2 equivalent.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用分布式发电提高能源效率;坎佩切工程学院食堂,墨西哥
在目前的工作中,对位于坎佩切市自治大学工程学院的自助餐厅进行了整体设计。研究了光伏发电的四种场景。14个光伏组件,每个440个,方位角180º,倾斜角15º;另一个与前一个相似,但斜率为19.85º。下图为24个440个光伏组件的排列,方位角为218º,坡度为15º。最后一种布置由24个440个光伏组件组成,方位角为218º,坡度为19.85º。所有这些都与经济方面有关,以便在最短的恢复时间内获得更高的工厂效率。采用了国家可再生能源实验室(NREL)开发的免费软件系统顾问模型(SAM)。在2020年1月至2021年3月期间,还对墨西哥的Gran Demanda Media Ordinaria en msamxico (GDMO de CFE)进行了完整的季节性分析。最好的结果是发电量17,570千瓦时。容量系数19%。能源性能1,671 kWh/kW。性能关系0.74。平地成本5.39美分/千瓦时。0.6年的投资回报。该光伏电站防止向大气中排放778.85千克二氧化碳当量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IBM Journal of Research and Development
IBM Journal of Research and Development 工程技术-计算机:硬件
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The IBM Journal of Research and Development is a peer-reviewed technical journal, published bimonthly, which features the work of authors in the science, technology and engineering of information systems. Papers are written for the worldwide scientific research and development community and knowledgeable professionals. Submitted papers are welcome from the IBM technical community and from non-IBM authors on topics relevant to the scientific and technical content of the Journal.
期刊最新文献
Use of a smartwatch for home blood pressure measurement Numerical modeling of the behavior of a lithium battery after a collision Disaster Resilient Cities in Nepal: Disaster Management Efforts of Biratnagar Metropolitan City Status of Invasive Alien Plant species in Dhankuta Municipality Perceived Learning Environment: A Case of BBA Program at Dhankuta Multiple Campus
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1