High Performance Blood Glucose Sensor using Charge Transfer Technique

Seung-Ro Lee, T. Hizawa, K. Sawada, H. Takao, M. Ishida
{"title":"High Performance Blood Glucose Sensor using Charge Transfer Technique","authors":"Seung-Ro Lee, T. Hizawa, K. Sawada, H. Takao, M. Ishida","doi":"10.1109/SENSOR.2007.4300265","DOIUrl":null,"url":null,"abstract":"The charge transfer type blood glucose sensor (CTTGS) has been proposed. The CTTGS is an accumulation method H+ ion (gluconic acid) perception system. As compared to cyclic-voltammetry and ISFET, the performance was found to be excellent with span and range of 1445 mV and 200 mmol/L respectively. The sensitivity obtained for blood glucose level of the person was 29.06 mV/mmol with a non-linear error of 1%, which is acceptable for clinical application.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The charge transfer type blood glucose sensor (CTTGS) has been proposed. The CTTGS is an accumulation method H+ ion (gluconic acid) perception system. As compared to cyclic-voltammetry and ISFET, the performance was found to be excellent with span and range of 1445 mV and 200 mmol/L respectively. The sensitivity obtained for blood glucose level of the person was 29.06 mV/mmol with a non-linear error of 1%, which is acceptable for clinical application.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用电荷传递技术的高性能血糖传感器
提出了电荷转移型血糖传感器(CTTGS)。CTTGS是一种积累法H+离子(葡萄糖酸)感知系统。与循环伏安法和ISFET相比较,该方法的量程和量程分别为1445 mV和200 mmol/L。该方法对患者血糖水平的敏感性为29.06 mV/mmol,非线性误差为1%,可用于临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Biaxially Stretchable Interconnect with Liquid Alloy Joints on Flexible Substrate Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface Sliding Contact Micro-Bearing for Nano-Precision Sensing and Positioning Self-Sensing Quartz-Crystal Cantilever for Nanometric Sensing Fabrication and Characterization of a Hydrogen Sensor Based on Palladium Nanowires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1