{"title":"Transosseous Suture With an All-FiberWire Technique in Patellar Fracture Fixation","authors":"Ponrachai Wongthongsalee, Thanapon Chobpenthai","doi":"10.1097/BTO.0000000000000579","DOIUrl":null,"url":null,"abstract":"Background: Patellar fractures account for 0.5% to 1.5% of all bone fractures. Tension band wiring with heavy gauge steel wire and K-wires is traditionally procedure for treating patellar fractures. However, this method is associated with implant-related complications. Present study aimed to evaluate functional clinical outcomes of patellar fracture fixation with transosseous suture using an all-FiberWire technique. Methods: This was a retrospective study involving 16 patellar fractures patients were repaired by open reduction and internal fixation with FiberWire using a 3-transosseous tunnel technique. The functional outcomes were evaluated with Tegner-Lysholm and Bostman scoring. We also evaluated clinical and radiologic outcomes. Results: The mean time to bony union was 8.87±1.54 weeks (range, 7 to 12 wk). The mean Bostman score at final follow-up was 27.13±2.5 (range, 21 to 30), and mean Lysholm score at final follow-up was 90.69±5.75 (range, 83 to 100). Fractures healed in all patients, with no fixation failures. Minor loss of reduction (<2 mm) were observed in 3 patients (18.75%). No patient has reoperation. One patient developed knee stiffness, with an infected hematoma 10 weeks postoperatively. None of patients developed anterior knee pain postoperatively. Two patients (12.5%) developed mild localized pain from prominent suture knots. There were no significant implant-related complications and no repeat surgery was necessary. Conclusions: The use of nonmetallic sutures with an all-FiberWire technique in patellar fracture fixation avoids implant-associated complications and possibility of a second surgery to remove metal implants. Nonmetallic high-resistance FiberWire matches traditional metallic fixation, with a reduced risk of postoperative complications. Level of Evidence: Level IV (therapeutic).","PeriodicalId":45336,"journal":{"name":"Techniques in Orthopaedics","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTO.0000000000000579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Patellar fractures account for 0.5% to 1.5% of all bone fractures. Tension band wiring with heavy gauge steel wire and K-wires is traditionally procedure for treating patellar fractures. However, this method is associated with implant-related complications. Present study aimed to evaluate functional clinical outcomes of patellar fracture fixation with transosseous suture using an all-FiberWire technique. Methods: This was a retrospective study involving 16 patellar fractures patients were repaired by open reduction and internal fixation with FiberWire using a 3-transosseous tunnel technique. The functional outcomes were evaluated with Tegner-Lysholm and Bostman scoring. We also evaluated clinical and radiologic outcomes. Results: The mean time to bony union was 8.87±1.54 weeks (range, 7 to 12 wk). The mean Bostman score at final follow-up was 27.13±2.5 (range, 21 to 30), and mean Lysholm score at final follow-up was 90.69±5.75 (range, 83 to 100). Fractures healed in all patients, with no fixation failures. Minor loss of reduction (<2 mm) were observed in 3 patients (18.75%). No patient has reoperation. One patient developed knee stiffness, with an infected hematoma 10 weeks postoperatively. None of patients developed anterior knee pain postoperatively. Two patients (12.5%) developed mild localized pain from prominent suture knots. There were no significant implant-related complications and no repeat surgery was necessary. Conclusions: The use of nonmetallic sutures with an all-FiberWire technique in patellar fracture fixation avoids implant-associated complications and possibility of a second surgery to remove metal implants. Nonmetallic high-resistance FiberWire matches traditional metallic fixation, with a reduced risk of postoperative complications. Level of Evidence: Level IV (therapeutic).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全纤维丝经骨缝合在髌骨骨折固定中的应用
背景:髌骨骨折占所有骨折的0.5% ~ 1.5%。用大规格钢丝和k形钢丝张力带钢丝是治疗髌骨骨折的传统方法。然而,这种方法与种植体相关的并发症有关。本研究旨在评估全纤维丝技术经骨缝合固定髌骨骨折的功能临床结果。方法:回顾性研究16例髌骨骨折患者,采用3-经骨隧道技术,采用纤维丝切开复位内固定修复。功能结果采用Tegner-Lysholm和Bostman评分进行评估。我们还评估了临床和放射学结果。结果:平均骨愈合时间为8.87±1.54周(7 ~ 12周)。末次随访时Bostman平均评分为27.13±2.5分(范围21 ~ 30),Lysholm平均评分为90.69±5.75分(范围83 ~ 100)。所有患者骨折均愈合,无固定失败。3例患者(18.75%)观察到轻度复位损失(< 2mm)。无患者再手术。1例患者术后10周出现膝关节僵硬,并发感染性血肿。术后无患者出现膝关节前侧疼痛。2例(12.5%)患者因缝合结突出而出现轻度局部疼痛。无明显的种植体相关并发症,无需重复手术。结论:在髌骨骨折固定中使用全纤维线技术的非金属缝线避免了植入物相关的并发症和第二次手术取出金属植入物的可能性。非金属高电阻FiberWire与传统金属固定相匹配,降低了术后并发症的风险。证据等级:IV级(治疗性)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
31
期刊介绍: The purpose of Techniques in Orthopaedics is to provide information on the latest orthopaedic procedure as they are devised and used by top orthopaedic surgeons. The approach is technique-oriented, covering operations, manipulations, and instruments being developed and applied in such as arthroscopy, arthroplasty, and trauma. Each issue is guest-edited by an expert in the field and devoted to a single topic.
期刊最新文献
A Derotational Corrective Osteotomy in a Torsional Malaligned Femoral Shaft Fracture Around a Prior Stuck Intramedullary Nail Optimizing Femoral Tunnel Placement in ACL Reconstruction: Effect of a 70-degree Arthroscope and Portal Position Intraoperative O-arm Use for Physeal Bar Excision Rambam Hospital Protocol for Treatment of Early Stages of Legg-Calve-Perthes Disease Cup and Cage Reconstruction for Metastatic Acetabular Lesions Provides Functional Improvement and Cost-efficiency
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1