{"title":"A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS","authors":"H. Yoon","doi":"10.5478/MSL.2015.6.4.116","DOIUrl":null,"url":null,"abstract":"Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reli- able biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 µL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r 2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and thera- peutic monitoring of Fabry disease patients.","PeriodicalId":18238,"journal":{"name":"Mass Spectrometry Letters","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2015-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass Spectrometry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5478/MSL.2015.6.4.116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 1
Abstract
Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reli- able biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 µL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r 2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and thera- peutic monitoring of Fabry disease patients.