Study of the Hardness and Microstructure of Quenched ABNT 1045 Steel Bars and Their Relationship to the Lumped Thermal Systems

L. G. Barbosa, Luciano Goetems, Carlos Alexandre Rech, Fábio Luis Knewitz
{"title":"Study of the Hardness and Microstructure of Quenched ABNT 1045 Steel Bars and Their Relationship to the Lumped Thermal Systems","authors":"L. G. Barbosa, Luciano Goetems, Carlos Alexandre Rech, Fábio Luis Knewitz","doi":"10.5923/J.IJMEE.20190701.01","DOIUrl":null,"url":null,"abstract":"Lumped thermal systems are characterized by uniform interior temperature during heat transfer processes, having as only important factor the time. Thus, the present research has proposed to investigate one of these systems in order to determine a maximum radius along which the microstructure and hardness are homogeneous after performing a quenching heat treatment. Cylindrical samples with diameters equal to 12.7, 14.0, 15.0, 16.0, 16.5, 17.0, 18.0 and 19.0 mm of ABNT 1045 steel were produced with ratios of 20:1 between the length and radius. Afterwards, they were heated in a kiln to 845°C, where they remained between 30 minutes (smaller diameter) and 45 minutes (larger diameter), for complete austenitization. Thereafter, they were rapidly cooled in water to room temperature. With the samples already sectioned, the hardness values were measured and the microstructures along the radius were verified by metallography. The results indicated that for the samples of 12.7, 14.0 and 15.0 mm, the hardness measurements were the same in the center, in the middle of the radius and near the surface, characterizing martensitic microstructures that were corroborated by the metallographies. For the samples of 16.0, 16.5, 17.0, 18.0 and 19.0 mm, the results were not homogeneous along the radius. In this way, it has been found that the maximum diameter at which ABNT 1045 steel cylindrical bars behave as lumped thermal systems is 15.0 mm.","PeriodicalId":23734,"journal":{"name":"World Academy of Science, Engineering and Technology, International Journal of Materials and Metallurgical Engineering","volume":"122 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Academy of Science, Engineering and Technology, International Journal of Materials and Metallurgical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.IJMEE.20190701.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Lumped thermal systems are characterized by uniform interior temperature during heat transfer processes, having as only important factor the time. Thus, the present research has proposed to investigate one of these systems in order to determine a maximum radius along which the microstructure and hardness are homogeneous after performing a quenching heat treatment. Cylindrical samples with diameters equal to 12.7, 14.0, 15.0, 16.0, 16.5, 17.0, 18.0 and 19.0 mm of ABNT 1045 steel were produced with ratios of 20:1 between the length and radius. Afterwards, they were heated in a kiln to 845°C, where they remained between 30 minutes (smaller diameter) and 45 minutes (larger diameter), for complete austenitization. Thereafter, they were rapidly cooled in water to room temperature. With the samples already sectioned, the hardness values were measured and the microstructures along the radius were verified by metallography. The results indicated that for the samples of 12.7, 14.0 and 15.0 mm, the hardness measurements were the same in the center, in the middle of the radius and near the surface, characterizing martensitic microstructures that were corroborated by the metallographies. For the samples of 16.0, 16.5, 17.0, 18.0 and 19.0 mm, the results were not homogeneous along the radius. In this way, it has been found that the maximum diameter at which ABNT 1045 steel cylindrical bars behave as lumped thermal systems is 15.0 mm.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ABNT 1045淬火钢的硬度、显微组织及其与集总热系统关系的研究
集总热系统的特点是在传热过程中内部温度均匀,只有时间是重要因素。因此,本研究建议研究这些系统之一,以确定执行淬火热处理后组织和硬度均匀的最大半径。ABNT 1045钢的直径分别为12.7、14.0、15.0、16.0、16.5、17.0、18.0和19.0 mm的圆柱形试样,其长径比为20:1。之后,它们在窑中加热到845°C,在那里保持30分钟(小直径)到45分钟(大直径),以完成奥氏体化。之后,它们在水中迅速冷却到室温。在试样已切片的情况下,测量了试样的硬度值,并用金相法对试样沿半径方向的组织进行了验证。结果表明:对于12.7、14.0和15.0 mm的试样,其中心、半径中间和近表面的硬度测量值相同,表现为马氏体组织,金相学证实了这一点;对于16.0、16.5、17.0、18.0和19.0 mm的样品,沿半径方向的结果不均匀。通过这种方法,我们发现ABNT 1045型钢柱状棒表现为集总热系统的最大直径为15.0 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IMPACT TEST ANALYSIS OF NATURAL FIBRE REINFORCED POLYMER COMPOSITES FABRICATED WITH BAST FIBRES FOR INDUSTRIAL/HOUSEHOLD APPLICATIONS ADDRESSING THE DRAWBACKS OF PEROVSKITE PHOTOVOLTAICS TO IMPROVE SOLAR ENERGY TECHNOLOGIES: A REVIEW ELECTRONIC STRUCTURES OF MnGe THEORETICAL AND NUMERICAL ANALYSES OF SHORT NATURAL FIBERS ORIENTATION IN THERMOPLASTIC MATRIX NEW EXPERIMENTAL ANALYTICAL APPROACH TO STUDY THE EFFECTS OF TEMPERATURE AND IRRADIANCE ON THE PHYSICAL PARAMETERS OF THE SOLAR PHOTOVOLTAIC MODULE IN SUNNY AND TEMPERATE ZONES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1