{"title":"Hysteresis study techniques and results for accelerator magnets with unipolar current excitation","authors":"B. Brown","doi":"10.1109/PAC.1999.792288","DOIUrl":null,"url":null,"abstract":"Using an automated magnet measurement system employing a variety of current excitation ramps, extensive studies of the hysteretic behavior of magnet strength have been carried out. An analytic description which is accurate at better than 0.1% has been achieved. Prescriptions for setting field strength using these formulas will be adequate for multi-energy operation of the Fermilab Main Injector, for deceleration in the Main Injector and Accumulator and for multi-energy operation of various beamline magnets. An overview of this work is provided. Important regularities of the magnet behavior are identified.","PeriodicalId":20453,"journal":{"name":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","volume":"8 1","pages":"3315-3317 vol.5"},"PeriodicalIF":0.0000,"publicationDate":"1999-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAC.1999.792288","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Using an automated magnet measurement system employing a variety of current excitation ramps, extensive studies of the hysteretic behavior of magnet strength have been carried out. An analytic description which is accurate at better than 0.1% has been achieved. Prescriptions for setting field strength using these formulas will be adequate for multi-energy operation of the Fermilab Main Injector, for deceleration in the Main Injector and Accumulator and for multi-energy operation of various beamline magnets. An overview of this work is provided. Important regularities of the magnet behavior are identified.