Single-Source Multiaxis Cold-Atom Interferometer in a Centimeter-Scale Cell.

Yun-Jhih Chen, Azure Hansen, Gregory W Hoth, Eugene Ivanov, Bruno Pelle, John Kitching, Elizabeth A Donley
{"title":"Single-Source Multiaxis Cold-Atom Interferometer in a Centimeter-Scale Cell.","authors":"Yun-Jhih Chen, Azure Hansen, Gregory W Hoth, Eugene Ivanov, Bruno Pelle, John Kitching, Elizabeth A Donley","doi":"10.1103/physrevapplied.12.014019","DOIUrl":null,"url":null,"abstract":"<p><p>Using point-source atom interferometry (PSI), we characterize the sensitivity of a multiaxis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman-laser beams and the projection of the rotation vector onto the plane perpendicular to that direction. The sensitivities for the magnitude and direction of the rotation-vector measurement are 0.033°/s and 0.27° with an averaging time of 1 s, respectively. The fractional acceleration sensitivity <math><mrow><mi>δ</mi> <mi>g</mi> <mo>/</mo> <mi>g</mi></mrow> </math> is <math><mrow><mn>1.6</mn> <mo>×</mo> <msup><mrow><mn>10</mn></mrow> <mrow><mo>-</mo> <mn>5</mn></mrow> </msup> <mo>/</mo> <mo>√</mo> <mtext>Hz</mtext></mrow> </math> . The sensitivity can be increased by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. PSI resolves a rotation vector in a plane by measuring a phase gradient. This two-dimensional rotation sensitivity may be specifically important for applications such as tracking the precession of a rotation vector and gyrocompassing.</p>","PeriodicalId":23290,"journal":{"name":"Transactions of The Faraday Society","volume":"66 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11555935/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of The Faraday Society","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1103/physrevapplied.12.014019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Using point-source atom interferometry (PSI), we characterize the sensitivity of a multiaxis gyroscope based on free-space Raman interrogation of a single source of cold atoms in a glass vacuum cell. The instrument simultaneously measures the acceleration in the direction of the Raman-laser beams and the projection of the rotation vector onto the plane perpendicular to that direction. The sensitivities for the magnitude and direction of the rotation-vector measurement are 0.033°/s and 0.27° with an averaging time of 1 s, respectively. The fractional acceleration sensitivity δ g / g is 1.6 × 10 - 5 / Hz . The sensitivity can be increased by increasing the Raman interrogation time, allowing the cold-atom cloud to expand further, correcting the fluctuations in the initial cloud shape, and reducing sources of technical noise. PSI resolves a rotation vector in a plane by measuring a phase gradient. This two-dimensional rotation sensitivity may be specifically important for applications such as tracking the precession of a rotation vector and gyrocompassing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
厘米级电池中的单源多轴冷原子干涉仪。
我们利用点源原子干涉测量法(PSI),鉴定了基于玻璃真空池中单个冷原子源的自由空间拉曼探测的多轴陀螺仪的灵敏度。该仪器可同时测量拉曼激光束方向上的加速度以及旋转矢量在垂直于该方向的平面上的投影。旋转矢量测量的大小和方向灵敏度分别为 0.033°/s 和 0.27°,平均时间为 1 秒。分数加速度灵敏度 δ g / g 为 1.6 × 10 - 5 / √ Hz。灵敏度可以通过延长拉曼探测时间、让冷原子云进一步扩大、校正初始云形状的波动以及减少技术噪声源来提高。PSI 通过测量相位梯度来解析平面内的旋转矢量。这种二维旋转灵敏度对于跟踪旋转矢量的前冲和陀螺绕射等应用可能特别重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Uterine Artery Embolization: A boon for Uterine Arteriovenous Malformation. Transporters for Bile Formation in Physiology and Pathophysiology. Circulating extracellular vesicles carrying Firmicutes reflective of the local immune status may predict clinical response to pembrolizumab in urothelial carcinoma patients. Exploring the Clinical Utility of the Music Therapy Assessment Tool for Awareness in Disorders of Consciousness (MATADOC) with People with End-Stage Dementia. Single-pass needle trajectory for lateral femoral cutaneous nerve and PENG blocks, and caution to avoid injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1