TOTAL FOCUSING METHOD BASED ULTRASONIC PHASED ARRAY IMAGING IN THICK STRUCTURES

Sumana, Anish Kumar
{"title":"TOTAL FOCUSING METHOD BASED ULTRASONIC PHASED ARRAY IMAGING IN THICK STRUCTURES","authors":"Sumana, Anish Kumar","doi":"10.1115/1.4050802","DOIUrl":null,"url":null,"abstract":"\n Ultrasonic non-destructive testing traditionally uses a conventional monolithic transducer. An approach similar to this comprising of independent single transmissions but with reception performed by all the elements in phased array ultrasonics is known as Full Matrix Capture (FMC). The acquired data is processed by Total Focusing Method (TFM). Conventional FMC-TFM has limitations in the inspection at large depth in attenuating materials due to single element transmission. To improve the beam forming process, coherent recombination of the plane wave with specific angles is utilized in transmission and the same aperture is used for the reception in Plane Wave Imaging (PWI). A new methodology called Angle Beam Virtual Source FMC-TFM (ABVSFMC-TFM) is proposed to inspect thick attenuating materials such as nickel base alloys. The ABVSFMC method leads to improved Signal to Noise Ratio (SNR) as compared to the conventional FMC due to increased energy with directivity during transmission using a group of elements and improved divergence as compared to the PWI due to a small virtual source near the sample surface. In the present paper, FMC-TFM, PWI-TFM and ABVSFMC-TFM methods are compared for inspection of thick nickel base superalloy (Alloy 617) with slots at various depths in the range of 25-200 mm. Optimization of the incidence angle has been performed by beam computation in CIVA software. Results obtained by CIVA simulations are discussed and also compared for the three methods.","PeriodicalId":52294,"journal":{"name":"Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems","volume":"27 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/1.4050802","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Ultrasonic non-destructive testing traditionally uses a conventional monolithic transducer. An approach similar to this comprising of independent single transmissions but with reception performed by all the elements in phased array ultrasonics is known as Full Matrix Capture (FMC). The acquired data is processed by Total Focusing Method (TFM). Conventional FMC-TFM has limitations in the inspection at large depth in attenuating materials due to single element transmission. To improve the beam forming process, coherent recombination of the plane wave with specific angles is utilized in transmission and the same aperture is used for the reception in Plane Wave Imaging (PWI). A new methodology called Angle Beam Virtual Source FMC-TFM (ABVSFMC-TFM) is proposed to inspect thick attenuating materials such as nickel base alloys. The ABVSFMC method leads to improved Signal to Noise Ratio (SNR) as compared to the conventional FMC due to increased energy with directivity during transmission using a group of elements and improved divergence as compared to the PWI due to a small virtual source near the sample surface. In the present paper, FMC-TFM, PWI-TFM and ABVSFMC-TFM methods are compared for inspection of thick nickel base superalloy (Alloy 617) with slots at various depths in the range of 25-200 mm. Optimization of the incidence angle has been performed by beam computation in CIVA software. Results obtained by CIVA simulations are discussed and also compared for the three methods.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于全聚焦法的厚结构超声相控阵成像
超声波无损检测传统上使用传统的单片换能器。与此类似的方法包括独立的单传输,但由相控阵超声波中的所有元件进行接收,称为全矩阵捕获(FMC)。采集的数据采用全聚焦法(TFM)进行处理。传统的FMC-TFM由于单元件传输,在衰减材料的大深度检测中存在局限性。为了改善波束形成过程,在平面波成像(PWI)中,采用特定角度的平面波相干重组进行传输,并采用相同孔径进行接收。提出了一种角光束虚拟源FMC-TFM (ABVSFMC-TFM)检测镍基合金等厚衰减材料的新方法。与传统的FMC相比,ABVSFMC方法提高了信噪比(SNR),这是由于在使用一组元件的传输过程中增加了指向性能量,而与PWI相比,ABVSFMC方法提高了散度,这是由于样品表面附近有一个小的虚拟源。本文比较了FMC-TFM、PWI-TFM和ABVSFMC-TFM三种方法对25- 200mm范围内不同深度的厚镍基高温合金(Alloy 617)槽的检测效果。在CIVA软件中通过光束计算对入射角进行了优化。讨论并比较了三种方法的CIVA仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
9.10%
发文量
25
期刊最新文献
Enhancement of Contact Acoustic Nonlinearity Effect in a Concrete Beam using Ambient Vibrations Identification of spalling fault size of ball bearing based on modified energy value Deep Learning based Time-Series Classification for Robotic Inspection of Pipe Condition using Non-Contact Ultrasonic Testing AI-enabled crack-length estimation from acoustic emission signal signatures Longitudinal wave propagation in an elastic cylinder embedded in a viscoelastic fluid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1