Distance and Location of Both Mobile Phones and Health Care Units: Determines the Interference Level

S. Helhel, Zeynep Colak, S. Ozen
{"title":"Distance and Location of Both Mobile Phones and Health Care Units: Determines the Interference Level","authors":"S. Helhel, Zeynep Colak, S. Ozen","doi":"10.5923/J.AJBE.20110102.14","DOIUrl":null,"url":null,"abstract":"Million mobile phone holders in the country forces clinics and cellular phones have been started to be in concern as an electromagnetic interference (EMI) source in hospitals. Hospital buildings are very huge buildings that they are not allowing deep radio penetration through the hole those results in higher uplink power transmission (2W of maxi- mum). These two reasons were our motivation to make an investigation to examine the EMI issues surrounding medical equipment, due to interference from communication devices, including GSM900, GSM1800, and 3G digital mobile phones. Electromagnetic interference, particularly of the ECG and ted EEG device was observed, and exposure begins within the range of 1.25m. It has been observed that uplink power is not a reason of interference itself, but the locations of mobiles and health care units are also the reason of interference.","PeriodicalId":7620,"journal":{"name":"American Journal of Biomedical Engineering","volume":"6 1","pages":"78-82"},"PeriodicalIF":0.0000,"publicationDate":"2012-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5923/J.AJBE.20110102.14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Million mobile phone holders in the country forces clinics and cellular phones have been started to be in concern as an electromagnetic interference (EMI) source in hospitals. Hospital buildings are very huge buildings that they are not allowing deep radio penetration through the hole those results in higher uplink power transmission (2W of maxi- mum). These two reasons were our motivation to make an investigation to examine the EMI issues surrounding medical equipment, due to interference from communication devices, including GSM900, GSM1800, and 3G digital mobile phones. Electromagnetic interference, particularly of the ECG and ted EEG device was observed, and exposure begins within the range of 1.25m. It has been observed that uplink power is not a reason of interference itself, but the locations of mobiles and health care units are also the reason of interference.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
移动电话和保健单位的距离和位置:决定干扰水平
国家部队诊所的百万移动电话用户和移动电话作为医院的电磁干扰源已开始受到关注。医院建筑物是非常巨大的建筑物,它们不允许深无线电穿透孔,这导致更高的上行功率传输(最大2W)。这两个原因是我们进行调查的动机,以检查医疗设备周围的EMI问题,由于通信设备的干扰,包括GSM900, GSM1800和3G数字移动电话。观察到电磁干扰,特别是ECG和ted EEG设备,暴露开始于1.25m范围内。据观察,上行功率本身不是造成干扰的原因,但移动电话和保健单位的位置也是造成干扰的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impacts of Robotic Compliance and Bone Bending on Simulated in vivo Knee Kinematics. A Measurement-Quality Body-Worn Physiological Monitor for Use in Harsh Environments Network Dynamics and Spontaneous Oscillations in a Developing Neuronal Culture Cardiovascular Modifications and Stratification of the Arrhythmic Risk in Young and Master Athletes The mechanical properties of a porous ceramic derived from a 30 nm sized particle based powder of hydroxyapatite for potential hard tissue engineering applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1