Variations of pressure data from insoles in normal population during the 10meter walking test and an appropriate parameters’ extraction algorithm: a pilot study
D. Dimopoulos, Evangelos Kalogirou, D. Varvarousis, Vasilis Nakos, I. Manolis, Mohamed Hedi Boughariou, G. I. Vasileiadis, A. Ploumis
{"title":"Variations of pressure data from insoles in normal population during the 10meter walking test and an appropriate parameters’ extraction algorithm: a pilot study","authors":"D. Dimopoulos, Evangelos Kalogirou, D. Varvarousis, Vasilis Nakos, I. Manolis, Mohamed Hedi Boughariou, G. I. Vasileiadis, A. Ploumis","doi":"10.1109/SEEDA-CECNSM57760.2022.9932942","DOIUrl":null,"url":null,"abstract":"Our objective was to explore variations of pressure data from insole pressure sensors after a walking session and to produce an algorithm which extracts spatiotemporal gait parameters in close real time. In this study we performed a 10-meter stand up and walking test on 25 normal individuals. All subjects were walking at their comfortable speed during the test. The subjects were wearing in-soles equipped with 9 pressure sensors on each foot (the W-inshoe system by Medicapteurs). The W-inshoe system is simple, relatively cheap and reliable. System’s software is quite outdated, has multiple bugs and does not produce the appropriate numerical gait parameters, so we developed an algorithm to process the raw data from the insoles using MATLAB. The developed algorithm can successfully process the pressure data, remove noise, and produce the appropriate gait parameters accurately. Using the algorithm on our sampling pool, we procured the following results: Average peak pressure range was 644 to 1555 gram force (average: 1000gf, average stance period range was 0.64 to 0.85 seconds (average: 0. 76s) and double support period range was 0.17 to 22s (average: 0. 18s). Even though there were only 9 sensors in every insole, the data were sufficient to develop the algorithm. In the future, the algorithm could be used on a cloud-based application to extract pressure and spatiotemporal gait parameters from a simple and reliable insole system.","PeriodicalId":68279,"journal":{"name":"计算机工程与设计","volume":"220 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"计算机工程与设计","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.1109/SEEDA-CECNSM57760.2022.9932942","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Our objective was to explore variations of pressure data from insole pressure sensors after a walking session and to produce an algorithm which extracts spatiotemporal gait parameters in close real time. In this study we performed a 10-meter stand up and walking test on 25 normal individuals. All subjects were walking at their comfortable speed during the test. The subjects were wearing in-soles equipped with 9 pressure sensors on each foot (the W-inshoe system by Medicapteurs). The W-inshoe system is simple, relatively cheap and reliable. System’s software is quite outdated, has multiple bugs and does not produce the appropriate numerical gait parameters, so we developed an algorithm to process the raw data from the insoles using MATLAB. The developed algorithm can successfully process the pressure data, remove noise, and produce the appropriate gait parameters accurately. Using the algorithm on our sampling pool, we procured the following results: Average peak pressure range was 644 to 1555 gram force (average: 1000gf, average stance period range was 0.64 to 0.85 seconds (average: 0. 76s) and double support period range was 0.17 to 22s (average: 0. 18s). Even though there were only 9 sensors in every insole, the data were sufficient to develop the algorithm. In the future, the algorithm could be used on a cloud-based application to extract pressure and spatiotemporal gait parameters from a simple and reliable insole system.
期刊介绍:
Computer Engineering and Design is supervised by China Aerospace Science and Industry Corporation and sponsored by the 706th Institute of the Second Academy of China Aerospace Science and Industry Corporation. It was founded in 1980. The purpose of the journal is to disseminate new technologies and promote academic exchanges. Since its inception, it has adhered to the principle of combining depth and breadth, theory and application, and focused on reporting cutting-edge and hot computer technologies. The journal accepts academic papers with innovative and independent academic insights, including papers on fund projects, award-winning research papers, outstanding papers at academic conferences, doctoral and master's theses, etc.