Signal subspace fusion of uncalibrated sensors with application in SAR, diagnostic medicine and video processing

M. Soumekh
{"title":"Signal subspace fusion of uncalibrated sensors with application in SAR, diagnostic medicine and video processing","authors":"M. Soumekh","doi":"10.1109/ICIP.1997.632090","DOIUrl":null,"url":null,"abstract":"This paper addresses the problem of fusing the information content of two uncalibrated sensors. This problem arises in registering images of a scene when it is viewed via two different sensory systems, or detecting change in a scene when it is viewed at two different time points by a sensory system, or via two different sensory systems or observation channels. We are concerned with sensory systems which have not only a relative shift, scaling and rotational calibration error, but also an unknown point spread function (that is time-varying for a single sensor, or different for two sensors). By modeling one image in terms of an unknown linear combination of the other image, its powers and their spatially-transformed (shift, rotation and scaling) versions, a signal subspace processing is developed for fusing uncalibrated sensors. The proposed method is shown to be applicable in moving target detection (MTD) using monopulse synthetic aperture radar (SAR) with uncalibrated radars. Results are shown for video, magnetic resonance images of a human brain, moving target detector monopulse SAR, and registration of SAR images of a target obtained via two different radars or at different coordinates by the same radar for automatic target recognition (ATR).","PeriodicalId":92344,"journal":{"name":"Computer analysis of images and patterns : proceedings of the ... International Conference on Automatic Image Processing. International Conference on Automatic Image Processing","volume":"1 1","pages":"280-283 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer analysis of images and patterns : proceedings of the ... International Conference on Automatic Image Processing. International Conference on Automatic Image Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIP.1997.632090","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper addresses the problem of fusing the information content of two uncalibrated sensors. This problem arises in registering images of a scene when it is viewed via two different sensory systems, or detecting change in a scene when it is viewed at two different time points by a sensory system, or via two different sensory systems or observation channels. We are concerned with sensory systems which have not only a relative shift, scaling and rotational calibration error, but also an unknown point spread function (that is time-varying for a single sensor, or different for two sensors). By modeling one image in terms of an unknown linear combination of the other image, its powers and their spatially-transformed (shift, rotation and scaling) versions, a signal subspace processing is developed for fusing uncalibrated sensors. The proposed method is shown to be applicable in moving target detection (MTD) using monopulse synthetic aperture radar (SAR) with uncalibrated radars. Results are shown for video, magnetic resonance images of a human brain, moving target detector monopulse SAR, and registration of SAR images of a target obtained via two different radars or at different coordinates by the same radar for automatic target recognition (ATR).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
无标定传感器信号子空间融合及其在SAR、诊断医学和视频处理中的应用
本文研究了两个未标定传感器信息内容的融合问题。当一个场景通过两个不同的感官系统被观看时,这个问题出现在注册场景图像时,或者当一个场景在两个不同的时间点被一个感官系统观看时,或者通过两个不同的感官系统或观察通道检测场景的变化时。我们关注的传感系统不仅具有相对移位、缩放和旋转校准误差,而且具有未知的点扩展函数(对于单个传感器是时变的,或者对于两个传感器是不同的)。通过根据另一图像的未知线性组合,其功率及其空间变换(移位,旋转和缩放)版本对一幅图像进行建模,开发了一种用于融合未校准传感器的信号子空间处理。结果表明,该方法适用于无标定雷达单脉冲合成孔径雷达的运动目标检测。结果显示了视频,人脑的磁共振图像,运动目标探测器单脉冲SAR,以及通过两个不同的雷达或在不同的坐标由同一雷达获得的目标的SAR图像的配准自动目标识别(ATR)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computer Analysis of Images and Patterns: 19th International Conference, CAIP 2021, Virtual Event, September 28–30, 2021, Proceedings, Part I Computer Analysis of Images and Patterns: 19th International Conference, CAIP 2021, Virtual Event, September 28–30, 2021, Proceedings, Part II Computer Analysis of Images and Patterns: CAIP 2019 International Workshops, ViMaBi and DL-UAV, Salerno, Italy, September 6, 2019, Proceedings Computer Analysis of Images and Patterns: 18th International Conference, CAIP 2019, Salerno, Italy, September 3–5, 2019, Proceedings, Part I Computer Analysis of Images and Patterns: 18th International Conference, CAIP 2019, Salerno, Italy, September 3–5, 2019, Proceedings, Part II
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1