Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Open Dentistry Journal Pub Date : 2022-05-01 DOI:10.3390/dj10050075
Adityakrisna Yoshi Putra Wigianto, Y. Ishida, Takashi Matsuda, T. Goto, Megumi Watanabe, T. Ichikawa
{"title":"Novel Magnetic Attachment System Manufactured Using High-Frequency Heat Treatment and Stamp Technique: Introduction and Basic Performance","authors":"Adityakrisna Yoshi Putra Wigianto, Y. Ishida, Takashi Matsuda, T. Goto, Megumi Watanabe, T. Ichikawa","doi":"10.3390/dj10050075","DOIUrl":null,"url":null,"abstract":"Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.","PeriodicalId":47284,"journal":{"name":"Open Dentistry Journal","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Dentistry Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/dj10050075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Recently, a novel magnetic attachment with extremely low cost and high performance was developed. This article aims to introduce a novel magnetic attachment and to evaluate its basic eligibility for denture retention in clinical practice. The novel magnetic attachment system used in this study was the direct-bonding root-keeper-type Magteeth™ MT800 (MagneDesign, Nagoya, Japan). The retentive force without displacement (position 0) and after horizontal displacement to positions 0.5, 1, 1.5, 2, 2.5, and 3 mm were measured. The values relative to the retentive force without displacement were gradually decreased to 82.7 ± 16.3%, 68.8 ± 17.1%, 62.4 ± 15%, 47.2 ± 13.1%, 35.7 ± 9.9%, and 20.7 ± 6.5%, respectively. The retentive force and magnetic field strength did not change significantly after the load test (100 N load, 10,000 times). No new gap between the metal and resin was found in the root keeper- and magnet assembly-embedded blocks after the load test. Some scratches on magnetic assembly and root keeper surface, while no change in the resin texture after the load test were observed. Based on the findings of this preliminary study, this novel low-cost magnetic attachment exhibited favorable retention, strength, and durability for clinical use.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用高频热处理和冲压技术制造的新型磁性附着系统:介绍及基本性能
近年来,研制出了一种低成本、高性能的新型磁性附着体。本文旨在介绍一种新型磁性附着体,并评估其在临床实践中用于义齿固位的基本资格。本研究中使用的新型磁性附着系统是直接粘接护根器型Magteeth™MT800 (MagneDesign, Nagoya, Japan)。测量无位移(0位)和水平位移至0.5、1、1.5、2、2.5、3mm位置后的固位力。相对于无位移固位力的数值逐渐降低,分别为82.7±16.3%、68.8±17.1%、62.4±15%、47.2±13.1%、35.7±9.9%和20.7±6.5%。负载试验(100 N负载,10000次)后,固相力和磁场强度无明显变化。负载试验后,在根保持器和磁铁组件嵌入块中未发现金属和树脂之间有新的间隙。磁性组件和护根器表面有划痕,但负载试验后树脂织构无变化。基于这项初步研究的结果,这种新型低成本磁性附着体具有良好的固位性、强度和耐久性,可用于临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Open Dentistry Journal
Open Dentistry Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.00
自引率
0.00%
发文量
86
期刊最新文献
Calculus as a Risk Factor for Periodontal Disease: Narrative Review on Treatment Indications When the Response to Scaling and Root Planing Is Inadequate. Caries Experience and Treatment Needs in Urban and Rural Environments in School-Age Children from Three Provinces of Ecuador: A Cross-Sectional Study Cannabidiol in Dentistry: A Scoping Review Effectiveness of 38% Silver Diamine Fluoride in Reducing Dentine Hypersensitivity on Exposed Root Surface in Older Chinese Adults: Study Protocol for a Randomised Double-Blind Study Challenges and Opportunities for Dental Education from COVID-19
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1