{"title":"Methods for comparing frequency response analysis measurements","authors":"S. Ryder","doi":"10.1109/ELINSL.2002.995909","DOIUrl":null,"url":null,"abstract":"This paper presents and evaluates a number of methods for comparing the results of frequency response analysis (FRA) measurements on power and distribution transformers. It begins with a short description of FRA and its uses. This includes a short review of the literature. Existing methods for comparing the results of FRA measurements are presented and discussed. A case is made for the increased use of statistical indicators. Two different statistical indicators are presented: the correlation coefficient and the spectrum deviation. The mathematical definition of each is given. The two indicators are applied to case studies, based on actual applications of FRA to power and distribution transformers. The performance of the indicators in these case studies is evaluated, considering the importance of avoiding both false positive and false negative results. It is concluded that the correlation coefficient is a useful statistical indicator in most circumstances. It is further concluded that the spectrum deviation is an unsuitable indicator, as it is particularly prone to give false negative results in some circumstances. Recommendations are made concerning the evaluation of other statistical indicators which may be proposed in the future.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"13 1","pages":"187-190"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"96","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995909","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 96

Abstract

This paper presents and evaluates a number of methods for comparing the results of frequency response analysis (FRA) measurements on power and distribution transformers. It begins with a short description of FRA and its uses. This includes a short review of the literature. Existing methods for comparing the results of FRA measurements are presented and discussed. A case is made for the increased use of statistical indicators. Two different statistical indicators are presented: the correlation coefficient and the spectrum deviation. The mathematical definition of each is given. The two indicators are applied to case studies, based on actual applications of FRA to power and distribution transformers. The performance of the indicators in these case studies is evaluated, considering the importance of avoiding both false positive and false negative results. It is concluded that the correlation coefficient is a useful statistical indicator in most circumstances. It is further concluded that the spectrum deviation is an unsuitable indicator, as it is particularly prone to give false negative results in some circumstances. Recommendations are made concerning the evaluation of other statistical indicators which may be proposed in the future.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
频率响应分析测量值的比较方法
本文介绍并评价了几种比较电力变压器和配电变压器频响分析(FRA)测量结果的方法。本文首先简要介绍联邦铁路局及其用途。这包括对文献的简短回顾。介绍和讨论了现有的比较FRA测量结果的方法。提出了增加使用统计指标的理由。提出了两种不同的统计指标:相关系数和谱偏差。给出了它们的数学定义。这两个指标应用于案例研究,基于电力和配电变压器FRA的实际应用。考虑到避免假阳性和假阴性结果的重要性,对这些案例研究中指标的表现进行了评估。在大多数情况下,相关系数是一个有用的统计指标。进一步得出结论,频谱偏差是一个不合适的指标,因为它特别容易在某些情况下给出假阴性结果。还就今后可能提出的其他统计指标的评价提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
After-installation test of HV extruded cable insulation Experimental investigation into the thermal-ageing of Kraft paper and mineral insulating oil Enhanced online PD evaluation on power transformers using wavelet techniques and frequency rejection filter for noise suppression On-line PD detection, requirements for practical use PD site location in distribution power cables
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1