{"title":"Cardiac Function Evaluation with Cine MRI of the Heart","authors":"A. Stillman, M. Jerosch-Herold","doi":"10.1002/0471142719.mia1104s015","DOIUrl":null,"url":null,"abstract":"This unit describes how to determine hemodynamic parameters of cardiac function such as ejection fraction (EF), end diastolic volume (EDV), end systolic volume (ESV), stroke volume (SV), and cardiac mass, based on experience using a Siemens 1.5 T Sonata scanner. Briefly, cine loops are acquired over several heartbeats, synchronized with the heart cycle by gating of the encoding steps with the patients electrocardiogram (ECG). Recently, it has become feasible to acquire cine loops in real time, although the temporal resolution is not optimal. Options discussed in this unit include breath hold versus free breathing, prospective triggering versus retrospective gating, and volumetric data sets versus biplanar approaches. Patient parameters such as heart rate or rhythm, degree of functional impairment, the presence of valvular disease, and the need to assess for jets from shunts or valve dysfunction are also treated.","PeriodicalId":100347,"journal":{"name":"Current Protocols in Magnetic Resonance Imaging","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2003-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Magnetic Resonance Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/0471142719.mia1104s015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This unit describes how to determine hemodynamic parameters of cardiac function such as ejection fraction (EF), end diastolic volume (EDV), end systolic volume (ESV), stroke volume (SV), and cardiac mass, based on experience using a Siemens 1.5 T Sonata scanner. Briefly, cine loops are acquired over several heartbeats, synchronized with the heart cycle by gating of the encoding steps with the patients electrocardiogram (ECG). Recently, it has become feasible to acquire cine loops in real time, although the temporal resolution is not optimal. Options discussed in this unit include breath hold versus free breathing, prospective triggering versus retrospective gating, and volumetric data sets versus biplanar approaches. Patient parameters such as heart rate or rhythm, degree of functional impairment, the presence of valvular disease, and the need to assess for jets from shunts or valve dysfunction are also treated.
本单元描述了如何根据使用西门子1.5 T Sonata扫描仪的经验,确定心功能的血流动力学参数,如射血分数(EF)、舒张末期容积(EDV)、收缩期末期容积(ESV)、卒中容积(SV)和心脏质量。简而言之,通过与患者心电图(ECG)的编码步骤门控,获得与心脏周期同步的几次心跳的电影循环。近年来,虽然时间分辨率不是最优的,但实时获取电影循环已经成为可能。本单元讨论的选项包括屏气与自由呼吸,前瞻性触发与回顾性门控,以及容积数据集与双平面入路。患者参数,如心率或节律,功能损害程度,瓣膜疾病的存在,以及需要评估分流或瓣膜功能障碍。