Point-of-Care Creatinine to Assist Clinical Decision Making in Suspected Sepsis in the Community

S. Simpson, J. Storrar, J. Ritchie, Khalid Alshawy, L. Ebah, S. Sinha, P. Elton, D. Darby, D. Poulikakos
{"title":"Point-of-Care Creatinine to Assist Clinical Decision Making in Suspected Sepsis in the Community","authors":"S. Simpson, J. Storrar, J. Ritchie, Khalid Alshawy, L. Ebah, S. Sinha, P. Elton, D. Darby, D. Poulikakos","doi":"10.1097/POC.0000000000000184","DOIUrl":null,"url":null,"abstract":"Abstract Guidance published from the National Institute for Health and Care Excellence in the United Kingdom for recognition and management for sepsis in acute hospital settings dictates that patients who present with suspected sepsis who are found to have acute kidney injury are high risk and should receive urgent treatment. We aimed at evaluating point-of-care (POC) creatinine (Cr) testing for diagnosis of acute kidney injury in the context of suspected sepsis out of hospital. Correlation was calculated using Pearson correlation coefficient, and agreement using Bland-Altman plot analysis was performed between StatSensor (Nova) handheld analyzer measurement in capillary samples and concurrent serum Cr measurement measured by laboratory method using Siemens Advia 2400 Jaffe from patients presenting in the emergency department and nursing home residents. Altogether 59 paired samples from 57 patients were obtained. Mean age was 76.6 years, and 29% were females. Pearson correlation between POC and serum Cr was r = 0.812, P < 0.001. Fifty-five of 59 were within the 95% limits of agreement. Three values outside the limits of agreement were observed in mean Cr values greater than 200 μmol/L. The POC Cr was higher than serum Cr in 85% of cases with an average difference between POC Cr and serum Cr of 32.5 μmol/L. An algorithm was agreed defining high-risk patients with suspected sepsis based on doubling of baseline Cr for individuals with known or suspected baseline values of less than 200 μmol/L.","PeriodicalId":20262,"journal":{"name":"Point of Care: The Journal of Near-Patient Testing & Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Point of Care: The Journal of Near-Patient Testing & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/POC.0000000000000184","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract Guidance published from the National Institute for Health and Care Excellence in the United Kingdom for recognition and management for sepsis in acute hospital settings dictates that patients who present with suspected sepsis who are found to have acute kidney injury are high risk and should receive urgent treatment. We aimed at evaluating point-of-care (POC) creatinine (Cr) testing for diagnosis of acute kidney injury in the context of suspected sepsis out of hospital. Correlation was calculated using Pearson correlation coefficient, and agreement using Bland-Altman plot analysis was performed between StatSensor (Nova) handheld analyzer measurement in capillary samples and concurrent serum Cr measurement measured by laboratory method using Siemens Advia 2400 Jaffe from patients presenting in the emergency department and nursing home residents. Altogether 59 paired samples from 57 patients were obtained. Mean age was 76.6 years, and 29% were females. Pearson correlation between POC and serum Cr was r = 0.812, P < 0.001. Fifty-five of 59 were within the 95% limits of agreement. Three values outside the limits of agreement were observed in mean Cr values greater than 200 μmol/L. The POC Cr was higher than serum Cr in 85% of cases with an average difference between POC Cr and serum Cr of 32.5 μmol/L. An algorithm was agreed defining high-risk patients with suspected sepsis based on doubling of baseline Cr for individuals with known or suspected baseline values of less than 200 μmol/L.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
护理点肌酐协助社区疑似败血症的临床决策
英国国家健康与护理卓越研究所发布的急性医院脓毒症识别和管理指南指出,发现有急性肾损伤的疑似脓毒症患者是高风险的,应该接受紧急治疗。我们的目的是评估在院外疑似败血症的情况下,即时护理(POC)肌酐(Cr)检测对急性肾损伤的诊断价值。采用Pearson相关系数计算相关性,并采用Bland-Altman图分析分析StatSensor (Nova)手持式分析仪测量的毛细管样品与实验室方法使用西门子Advia 2400 Jaffe同时测量的急诊科患者和养老院居民血清Cr之间的一致性。共获得57例患者的59个配对样本。平均年龄76.6岁,女性占29%。POC与血清Cr的Pearson相关性r = 0.812, P < 0.001。59例中有55例在95%的一致性范围内。平均Cr值大于200 μmol/L时,有3个值超出了一致性范围。85%的病例POC Cr高于血清Cr, POC Cr与血清Cr的平均差异为32.5 μmol/L。对于已知或疑似基线值低于200 μmol/L的个体,通过将基线Cr加倍来确定疑似脓毒症高危患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin Critical Care Nurses' Views and Experiences of Preanalytical Factors Influencing Point-of-Care Testing Rapid Assessment of Coagulation at the Point of Care With the Hemochron Signature Elite System Invited Product Profile: Detecting Antibodies for Lyme Disease at the Point of Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1