Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study

IF 0.2 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Journal of International Clinical Dental Research Organization Pub Date : 2022-04-30 DOI:10.5577/intdentres.2022.vol12.no1.6
S. Çelenk, O. Ataş, B. Ayna, A. Günay
{"title":"Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study","authors":"S. Çelenk, O. Ataş, B. Ayna, A. Günay","doi":"10.5577/intdentres.2022.vol12.no1.6","DOIUrl":null,"url":null,"abstract":"Aim: Using AutoCAD, we examined the microleakage of permanent molars in Class I restorations using a conventional posterior composite resin, a bulk-fill composite resin, and a high-viscosity glass-ionomer cement (HVGIC).\nMethodology: In total, 33 extracted noncarious third molars were used. Class I cavities were prepared. The teeth were randomly divided into three groups of 11 teeth each, as follows: Group A (Filtek Z550), Group B (Filtek Bulk-Fill Posterior Restorative), and Group C (EQUIA Fil). All specimens were stored for 24 h at 37 °C in distilled water. The teeth were thermocycled 1,000 times between 5 ± 2°C and 55 ± 2°C prior to immersion in 0.5% basic fuchsin for 24 h. Two mesiodistal cuts of each tooth were photographed under a stereomicroscope equipped with a digital camera. The dye-infiltrated surface area was measured.\nResults: Statistical evaluations were performed by one-way analysis of variance [ANOVA]. One-way ANOVA showed no significant difference between the three groups in microleakage (P = 0.07). However, the lowest microleakage ratio was seen in Group C (EQUIA Fil).  Similar results were obtained with all tested materials, but the lowest microleakage rate was obtained with EQUIA Fil (Group C).\nConclusion: In this study, the tested materials were not completely successful in eliminating microleakage, although the lowest microleakage rate was obtained with EQUIA Fil.\n \nHow to cite this article:\nÇelenk S, Ataş O, Ayna B, Günay A. Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study. Int Dent Res 2022;12(1):34-8. https://doi.org/10.5577/intdentres.2022.vol12.no1.6\n \nLinguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.","PeriodicalId":31322,"journal":{"name":"Journal of International Clinical Dental Research Organization","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of International Clinical Dental Research Organization","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5577/intdentres.2022.vol12.no1.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: Using AutoCAD, we examined the microleakage of permanent molars in Class I restorations using a conventional posterior composite resin, a bulk-fill composite resin, and a high-viscosity glass-ionomer cement (HVGIC). Methodology: In total, 33 extracted noncarious third molars were used. Class I cavities were prepared. The teeth were randomly divided into three groups of 11 teeth each, as follows: Group A (Filtek Z550), Group B (Filtek Bulk-Fill Posterior Restorative), and Group C (EQUIA Fil). All specimens were stored for 24 h at 37 °C in distilled water. The teeth were thermocycled 1,000 times between 5 ± 2°C and 55 ± 2°C prior to immersion in 0.5% basic fuchsin for 24 h. Two mesiodistal cuts of each tooth were photographed under a stereomicroscope equipped with a digital camera. The dye-infiltrated surface area was measured. Results: Statistical evaluations were performed by one-way analysis of variance [ANOVA]. One-way ANOVA showed no significant difference between the three groups in microleakage (P = 0.07). However, the lowest microleakage ratio was seen in Group C (EQUIA Fil).  Similar results were obtained with all tested materials, but the lowest microleakage rate was obtained with EQUIA Fil (Group C). Conclusion: In this study, the tested materials were not completely successful in eliminating microleakage, although the lowest microleakage rate was obtained with EQUIA Fil.   How to cite this article: Çelenk S, Ataş O, Ayna B, Günay A. Microleakage of two different posterior composites and a high-viscosity glass-ionomer cement: An in vitro study. Int Dent Res 2022;12(1):34-8. https://doi.org/10.5577/intdentres.2022.vol12.no1.6   Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种不同的后路复合材料和高粘度玻璃离子水泥的微渗漏:一项体外研究
目的:利用AutoCAD软件,采用常规后牙复合树脂、大块填充复合树脂和高粘度玻璃离子水门合剂(HVGIC)对I类修复体恒磨牙的微渗漏进行研究。方法:选择33颗无龋第三磨牙。制备了I类空腔。将牙随机分为3组,每组11颗牙,分别为:A组(Filtek Z550)、B组(Filtek块状填充后牙体)、C组(EQUIA Fil)。所有标本在37℃蒸馏水中保存24 h。牙齿在5±2℃至55±2℃的温度下热循环1000次,然后浸泡在0.5%碱性紫红中24小时。在配备数码相机的体视显微镜下拍摄每颗牙齿的两个中远端切口。测定染料浸润表面积。结果:采用单因素方差分析(ANOVA)进行统计学评价。单因素方差分析显示,三组间微渗漏无显著差异(P = 0.07)。而C组(EQUIA Fil)的微漏率最低。所有测试材料的结果相似,但EQUIA Fil (C组)的微漏率最低。结论:本研究中,尽管EQUIA Fil的微漏率最低,但测试材料并不能完全消除微漏。本文引用方式:Çelenk S, ataku O, Ayna B, g nay a .两种不同后部复合材料和高粘度玻璃离子水门体的微泄漏:体外研究。国际医学杂志,2016;12(1):34- 38。https://doi.org/10.5577/intdentres.2022.vol12.no1.6语言修改:本手稿中的英语已由至少两名专业编辑检查,他们都是英语母语者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
期刊最新文献
Evaluating the accuracy of intraoral scanners used in single-unit implant prosthesis construction Evaluation of the buccal bone thickness in the anterior maxillary region using cone-beam computed tomography Evaluation of the alveolar bone and lingual concavity in the posterior mandibular region based on cone-beam computed tomography data Evaluation of the effect of class II fixed orthodontic treatment on the periradicular bone structure of endodontically treated mandibular molar teeth using fractal dimension analysis Analyzing biomimetic dentistry YouTube videos' quality and content
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1