{"title":"Reply to Letter Regarding Article, \"Sirolimus-Eluting Stents Suppress Neointimal Formation Irrespective of Metallic Allergy\"(Letter to the Editor)","authors":"G. Nakazawa, K. Tanabe, K. Hara","doi":"10.1253/circj.cj-08-0759","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nMetallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated.\n\n\nMETHODS AND RESULTS\nThe present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19+/-0.49 mm vs 0.12+/-0.48 mm, p=0.55).\n\n\nCONCLUSION\nSES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus.","PeriodicalId":14644,"journal":{"name":"Japanese Circulation Journal-english Edition","volume":"16 1","pages":"1722"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Circulation Journal-english Edition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1253/circj.cj-08-0759","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
BACKGROUND
Metallic allergy is associated with restenosis following bare metal stent implantation, but the impact of metallic allergy on the outcome after implantation of drug-eluting stents (DES) has not been investigated.
METHODS AND RESULTS
The present study group consisted of 88 consecutive patients (109 lesions) who underwent percutaneous coronary intervention with sirolimus-eluting stents (SES). Follow-up angiography was obtained at 8 months in all patients. At that time, the patients underwent epicutaneous patch tests for nickel, chromate, molybdenum, manganese, and titanium, which were evaluated after 48 h of contact. The patch test was positive in 14 patients (16%) (5 for manganese, 3 for nickel, 1 for chromate, 1 for Nickel and manganese, and 4 for manganese and chromate). The binary restenosis rate in the patients with a positive patch test was similar to those with negative patch test (6.3% vs 6.5%, p=0.98). Serial quantitative coronary angiography analyses identified no significant differences in late lumen loss of in-stent segments between patients with positive patch test and those with negative patch test (0.19+/-0.49 mm vs 0.12+/-0.48 mm, p=0.55).
CONCLUSION
SES prevent restenosis irrespective of metallic allergy. The classic relationship between metallic allergy and in-stent restenosis, seen with bare metal stents, does not appear to arise with DES, possibly because of the immunosuppressive effect of sirolimus.