Tianpu Gu, Boteng Gong, D. Lu, Weiping Lin, Na Li, Qing He, R. Wei
{"title":"Influence of Corneal Topographic Parameters in the Decentration of Orthokeratology.","authors":"Tianpu Gu, Boteng Gong, D. Lu, Weiping Lin, Na Li, Qing He, R. Wei","doi":"10.1097/ICL.0000000000000580","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nTo investigate the lens decentration (LD) of orthokeratology (ortho-k) and the association between pretreatment corneal topographic parameters and LD of the ortho-k.\n\n\nMETHODS\nFifty right eyes of 50 myopes wearing ortho-k lenses were included in the prospective study. Corneal topography was conducted pretreatment to get topographic corneal parameters, including flat-K (K1); steep-K (K2); corneal astigmatism (CA), CA at 0 to 3 mm (3 mm-CA), 3 to 5 mm (5 mm-CA), 5 to 7 mm (7 mm-CA); surface asymmetry index (SAI); surface regularity index; the curvature of best-fit sphere; the diameter of cornea (DC); the distance from the corneal center to the corneal vertex (CCCV); flat eccentricity (E1), steep eccentricity (E2), and E1/E2 (E ratio); and the corneal curvature differences between the nasal and temporal quadrants at 0 to 3 mm (3 mm-Knt), and the corneal curvature differences between the superior and inferior quadrants at 0 to 3 mm (3 mm-Ksi), 5 mm-Knt (at 3-5 mm), 5 mm-Ksi (at 3-5 mm), 7 mm-Knt (at 5-7 mm), and 7 mm-Ksi (at 5-7 mm). The relationship between these cornea topographic parameters and LD of the ortho-k was tested using stepwise multiple linear regression models.\n\n\nRESULTS\nThe mean magnitude of LD was 0.51±0.23 mm (0.06-1.03 mm). According to the stepwise analysis, 4 factors were associated with the overall LD (P<0.01): SAI (β=0.252), CCCV (β=0.539), 5 mm-CA (β=-0.268), and 3 mm-Ksi (β=-0.374); 5 factors were associated with the horizontal LD (P<0.01): DC (β=0.205), CCCV (β=0.881), 3 mm-CA (β=-0.217), 5 mm-Knt (β=0.15), and 3 mm-Ksi (β=-0.18); and 3 factors were associated with the vertical LD (P<0.01): SAI (β=0.542), 5 mm-CA (β=-0.188), and 3 mm-Ksi (β=-0.213).\n\n\nCONCLUSION\nLens decentration is most common, but in most cases, the amount of LD is moderate and acceptable. The magnitude of LD can be predetermined by topographic corneal parameters. Surface asymmetry index, CCCV, 5 mm-Knt, and 3 mm-Ksi may be more preferable parameters in terms of the assessment of LD of ortho-k.","PeriodicalId":12216,"journal":{"name":"Eye & Contact Lens: Science & Clinical Practice","volume":"52 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens: Science & Clinical Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13
Abstract
OBJECTIVE
To investigate the lens decentration (LD) of orthokeratology (ortho-k) and the association between pretreatment corneal topographic parameters and LD of the ortho-k.
METHODS
Fifty right eyes of 50 myopes wearing ortho-k lenses were included in the prospective study. Corneal topography was conducted pretreatment to get topographic corneal parameters, including flat-K (K1); steep-K (K2); corneal astigmatism (CA), CA at 0 to 3 mm (3 mm-CA), 3 to 5 mm (5 mm-CA), 5 to 7 mm (7 mm-CA); surface asymmetry index (SAI); surface regularity index; the curvature of best-fit sphere; the diameter of cornea (DC); the distance from the corneal center to the corneal vertex (CCCV); flat eccentricity (E1), steep eccentricity (E2), and E1/E2 (E ratio); and the corneal curvature differences between the nasal and temporal quadrants at 0 to 3 mm (3 mm-Knt), and the corneal curvature differences between the superior and inferior quadrants at 0 to 3 mm (3 mm-Ksi), 5 mm-Knt (at 3-5 mm), 5 mm-Ksi (at 3-5 mm), 7 mm-Knt (at 5-7 mm), and 7 mm-Ksi (at 5-7 mm). The relationship between these cornea topographic parameters and LD of the ortho-k was tested using stepwise multiple linear regression models.
RESULTS
The mean magnitude of LD was 0.51±0.23 mm (0.06-1.03 mm). According to the stepwise analysis, 4 factors were associated with the overall LD (P<0.01): SAI (β=0.252), CCCV (β=0.539), 5 mm-CA (β=-0.268), and 3 mm-Ksi (β=-0.374); 5 factors were associated with the horizontal LD (P<0.01): DC (β=0.205), CCCV (β=0.881), 3 mm-CA (β=-0.217), 5 mm-Knt (β=0.15), and 3 mm-Ksi (β=-0.18); and 3 factors were associated with the vertical LD (P<0.01): SAI (β=0.542), 5 mm-CA (β=-0.188), and 3 mm-Ksi (β=-0.213).
CONCLUSION
Lens decentration is most common, but in most cases, the amount of LD is moderate and acceptable. The magnitude of LD can be predetermined by topographic corneal parameters. Surface asymmetry index, CCCV, 5 mm-Knt, and 3 mm-Ksi may be more preferable parameters in terms of the assessment of LD of ortho-k.