{"title":"Comparison of fire-resistant oils analysis methods performed by various oil laboratories","authors":"A. Okhlopkov, K. A. Orlov","doi":"10.32758/2782-3040-2022-0-5-62-68","DOIUrl":null,"url":null,"abstract":"The article presents a comparison of methods for analyzing fire-resistant oils carried out in the following companies: the central chemical laboratory of energy company No. 1, the Teplotekhnik testing center of OAO VTI, the laboratory of CHPP-A of energy company No. 1, the laboratory of CHPP-B of energy company No. 1, the TPP-B and TPP-G laboratories, central chemical laboratory of the energy company No. 3, testing laboratory of MITs GSM LLC. Methods for determining the deaeration time, foam formation, varnish formation potential, acid number, demulsification time, kinematic viscosity, content of water-soluble acids and alkalis, corrosion on steel plates, mass fraction of dissolved sludge, flash point in an open crucible, industrial purity class, water content, pH of water extract, water according to KF, mass fraction of mechanical impurities.","PeriodicalId":23763,"journal":{"name":"World of petroleum products","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World of petroleum products","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32758/2782-3040-2022-0-5-62-68","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The article presents a comparison of methods for analyzing fire-resistant oils carried out in the following companies: the central chemical laboratory of energy company No. 1, the Teplotekhnik testing center of OAO VTI, the laboratory of CHPP-A of energy company No. 1, the laboratory of CHPP-B of energy company No. 1, the TPP-B and TPP-G laboratories, central chemical laboratory of the energy company No. 3, testing laboratory of MITs GSM LLC. Methods for determining the deaeration time, foam formation, varnish formation potential, acid number, demulsification time, kinematic viscosity, content of water-soluble acids and alkalis, corrosion on steel plates, mass fraction of dissolved sludge, flash point in an open crucible, industrial purity class, water content, pH of water extract, water according to KF, mass fraction of mechanical impurities.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
各油品实验室耐火油分析方法的比较
本文介绍了以下公司进行的耐火油分析方法的比较:能源第一公司中心化学实验室、OAO VTI Teplotekhnik测试中心、能源第一公司CHPP-A实验室、能源第一公司CHPP-B实验室、能源第三公司中心化学实验室、TPP-B和TPP-G实验室、MITs GSM LLC测试实验室。除氧时间、泡沫形成、清油形成势、酸值、破乳时间、运动粘度的测定方法。水溶性酸和碱的含量,对钢板的腐蚀,溶解污泥的质量分数,开放坩埚中的闪点,工业纯度等级,含水量,水提取物的pH值,水按KF,机械杂质的质量分数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Extraction of phenol from phenolcontaining waters when using extractants Obtaining modern brands of road bitumen in the conditions of deepening oil refining at the JSC "SNPZ" The Central Volga Research Institute on Petroleum Refining: Achievements of Science for the Benefit of Production Medium alkaline alkylphenolate additives Development of Engineering Solutions on Upgrading Quality of Products up to Standard Requirements at Design Capacity at Gas Processing Plants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1