Enhancement of a recombinase-aided amplification assay using betaine and pullulan.

IF 1 4区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Journal of Liquid Chromatography & Related Technologies Pub Date : 2022-06-16 eCollection Date: 2022-06-01 DOI:10.1016/j.imj.2022.06.002
Jinrong Wang, Guowei Song, Yue Ming, Jing Pan, Ruiqing Zhang, Guohao Fan, Xinxin Shen, Xuejun Ma, Lixin Li
{"title":"Enhancement of a recombinase-aided amplification assay using betaine and pullulan.","authors":"Jinrong Wang, Guowei Song, Yue Ming, Jing Pan, Ruiqing Zhang, Guohao Fan, Xinxin Shen, Xuejun Ma, Lixin Li","doi":"10.1016/j.imj.2022.06.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Nucleic acid amplification enhancers suitable for use in a recombinase-aided amplification (RAA) assay were studied for the first time, and amplification of a long-fragment (509 bp) was initially explored.</p><p><strong>Methods: </strong>Using recombinant plasmids and clinical samples, RAA fluorescence and basic methods were used to evaluate the efficacy. The fluorescence method was evaluated by threshold time and fluorescence value, and the basic method was characterized by 2% agarose gel electrophoresis.</p><p><strong>Results: </strong>Taking a previously established RAA assay for HPV18 as an example, we demonstrated that the addition of 0.2 M, 0.4 M, and 0.6 M betaine and 10% pullulan could enhance the RAA. The new RAA assays with betaine and pullulan were named B-RAA and P-RAA, respectively. Using the B-RAA and P-RAA fluorescence methods, the threshold time values could be shortened by 1.72-2.32 minutes and 2.60 minutes, respectively, and the fluorescence values could be enhanced by 8847.25-9094.37 mv and 5250 mv, respectively. Using the basic method, the sensitivity could be increased 10-fold. We successfully amplified a long-fragment of 509 bp using a P-RAA assay with a sensitivity of 10<sup>2</sup> copies/µL (compared with 10<sup>3</sup> copies/µL in the RAA assay).</p><p><strong>Conclusions: </strong>Thus, we concluded that betaine and pullulan are effective additives to enhance the sensitivity of RAA assays.</p>","PeriodicalId":16295,"journal":{"name":"Journal of Liquid Chromatography & Related Technologies","volume":"12 1","pages":"73-80"},"PeriodicalIF":1.0000,"publicationDate":"2022-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10699723/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Liquid Chromatography & Related Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.imj.2022.06.002","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Nucleic acid amplification enhancers suitable for use in a recombinase-aided amplification (RAA) assay were studied for the first time, and amplification of a long-fragment (509 bp) was initially explored.

Methods: Using recombinant plasmids and clinical samples, RAA fluorescence and basic methods were used to evaluate the efficacy. The fluorescence method was evaluated by threshold time and fluorescence value, and the basic method was characterized by 2% agarose gel electrophoresis.

Results: Taking a previously established RAA assay for HPV18 as an example, we demonstrated that the addition of 0.2 M, 0.4 M, and 0.6 M betaine and 10% pullulan could enhance the RAA. The new RAA assays with betaine and pullulan were named B-RAA and P-RAA, respectively. Using the B-RAA and P-RAA fluorescence methods, the threshold time values could be shortened by 1.72-2.32 minutes and 2.60 minutes, respectively, and the fluorescence values could be enhanced by 8847.25-9094.37 mv and 5250 mv, respectively. Using the basic method, the sensitivity could be increased 10-fold. We successfully amplified a long-fragment of 509 bp using a P-RAA assay with a sensitivity of 102 copies/µL (compared with 103 copies/µL in the RAA assay).

Conclusions: Thus, we concluded that betaine and pullulan are effective additives to enhance the sensitivity of RAA assays.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用甜菜碱和拉普兰增强重组酶辅助扩增测定。
背景:首次研究了适用于重组酶辅助扩增(RAA)检测的核酸扩增增强剂,并初步探索了长片段(509 bp)的扩增:方法:利用重组质粒和临床样本,采用 RAA 荧光法和基本方法评估其有效性。荧光方法通过阈值时间和荧光值进行评估,基本方法通过 2% 琼脂糖凝胶电泳进行表征:结果:以之前建立的 HPV18 RAA 检测方法为例,我们证明了添加 0.2 M、0.4 M、0.6 M 甜菜碱和 10% 拉普兰可提高 RAA 的效果。含有甜菜碱和拉鲁兰的新型 RAA 检测方法分别被命名为 B-RAA 和 P-RAA。使用 B-RAA 和 P-RAA 荧光方法,阈值时间分别缩短了 1.72-2.32 分钟和 2.60 分钟,荧光值分别提高了 8847.25-9094.37 mv 和 5250 mv。使用基本方法,灵敏度可提高 10 倍。我们使用 P-RAA 方法成功扩增了 509 bp 的长片段,灵敏度为 102 个拷贝/微升(RAA 方法的灵敏度为 103 个拷贝/微升):因此,我们得出结论:甜菜碱和拉鲁兰是提高 RAA 检测灵敏度的有效添加剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
0.00%
发文量
29
审稿时长
4.9 months
期刊介绍: The Journal of Liquid Chromatography & Related Technologies is an internationally acclaimed forum for fast publication of critical, peer reviewed manuscripts dealing with analytical, preparative and process scale liquid chromatography and all of its related technologies, including TLC, capillary electrophoresis, capillary electrochromatography, supercritical fluid chromatography and extraction, field-flow technologies, affinity, and much more. New separation methodologies are added when they are developed. Papers dealing with research and development results, as well as critical reviews of important technologies, are published in the Journal.
期刊最新文献
Optimization of ion-pairing HPLC method for mutual separation of rare earth elements: unveiling the “diad-effect” appraisal utilizing periodic variations in their properties Magnetic solid phase extraction of methiocarb pesticide from food samples prior to HPLC analysis with magnetic activated carbon cloth/zinc aluminate (magnetic ACC@ZnAl2O4) composite HPTLC – densitometric method of analysis for estimation of efonidipine hydrochloride and telmisartan used in treatment of hypertension New method for rapid detection and simultaneous determination of prohibited adrenergic drugs in sports using thin layer chromatography and image processing Simultaneous quantification of two commonly used anticoagulant drugs and three hypolipidemic drugs in human plasma using gradient high-performance liquid chromatography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1