Heleen A. Bardelmeijer , Mariët Ouwehand , Jos H. Beijnen , Jan H.M. Schellens , Olaf van Tellingen
{"title":"Determination of cyclosporin A in human and mouse plasma by reversed-phase high-performance liquid chromatography","authors":"Heleen A. Bardelmeijer , Mariët Ouwehand , Jos H. Beijnen , Jan H.M. Schellens , Olaf van Tellingen","doi":"10.1016/S0378-4347(01)00389-9","DOIUrl":null,"url":null,"abstract":"<div><p>An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μ<em>M</em>. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μ<em>M</em> using 500 μl of human plasma and 0.28 μ<em>M</em> using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.</p></div>","PeriodicalId":15463,"journal":{"name":"Journal of Chromatography B: Biomedical Sciences and Applications","volume":"763 1","pages":"Pages 201-206"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0378-4347(01)00389-9","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B: Biomedical Sciences and Applications","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378434701003899","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
An isocratic reversed-phase high-performance liquid chromatographic method with ultraviolet detection at 227 nm has been validated for the determination of cyclosporin A in human and mouse plasma. The cyclosporin D analog PSC 833 was used as internal standard. Plasma samples were pretreated by liquid–liquid extraction with diethyl ether. A good chromatographic separation between cyclosporin A, the internal standard and two potentially interfering endogenous peaks was achieved using a stainless steel column packed with 5 μm Nova-Pak phenyl material operated at 72°C, and a mobile phase consisting of acetonitrile–methanol–water (20:52:28, v/v/v). The calibration curve for cyclosporin A in human plasma was linear over the tested concentration range of 0.11 to 5.34 μM. Murine plasma samples (200 μl) were diluted up to a total volume of 500 μl with blank human plasma and the concentrations were read from the calibration curve prepared in human plasma. The lower limit of quantitation was 0.11 μM using 500 μl of human plasma and 0.28 μM using 200 μl of mouse plasma. The validation data showed that the assay is sensitive, selective and reproducible for determination of cyclosporin A. The applicability was demonstrated in a pharmacokinetic experiment where mice received oral cyclosporin A.